HANNA HI-839800 25 Vial Thermo-Reactor

Update Terakhir
27-04-2016
Dilihat Sebanyak
96 kali
Lokasi
Jawa Barat - Bekasi
Harga
Kontak Kami
Bagikan
+ Penawaran

Perhatian!

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi lebih aman.

Spesifikasi HANNA HI-839800 25 Vial Thermo-Reactor

 The HI-839800 is an easy to use test tube heater with the capacity to perform up to 25 simultaneous digestions. Complete with a countdown timer, it can be used for timed or infinity testing procedures.

 

 

Robust and durable, the main body is machined from a single block of metal. Temperature within the block is controlled using a sophisticated electronic thermostat and can be verified by placing a thermometer in the temperature well provided.

 

 

The reactor is equipped with 6 pre-defined and 2 user-defined °C profiles.

  • Dedicated temperature profiles for COD and total phosphorus reactions are pre-set to 150°C
  • The total nitrogen analysis temperature is pre-set to 105°C
  • In adjustable temperature mode (50 to 150°C), the heater can be used for other samples that require different digestion temperatures

Key features
  • Heater block temperature is continuously evaluated and displayed on the LCD
  • Low temperature alert indicates that temperature is below set value
  • High temperature alert warns when temperature rises above the set value
  • Reactor has a thermal fuse that prevents overheating by disabling the heater
  • Countdown timer shows time remaining until heating element shuts off
  • A three hour countdown timer is ideal for timed digestion
  • The sound of a 'beep' indicates when the timer has expired and the heating element turns off
  • To operate in infinity mode, the timer can be used without the shut-off feature
  • Visual power indication
  • Green LED indicates power on
  • Blinking red LED warns if heater exceeds 50°C
  • Yellow LED indicates heating is active
  • For optimum safety, the block heater should always be used with a safety shield or other physical barrier placed between samples under test and operator

Accessories
  • Stainless steel test tube rack to hold 25 COD tubes - HI 740216
  • Bench top safety shield for use with HI-9800 series COD reactor/digester - HI 740217
Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Free Member
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
Rp. 123 / Unit
ALAT KESLING INDONESIA
Rp. 123 / Unit
ALAT KESLING INDONESIA