MEMMERT Humidity chamber HCP108
Perhatian!
Spesifikasi MEMMERT Humidity chamber HCP108
Properties
Control of standard components
Temperature | 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value |
---|---|
Humidity | active humidifying and de-humidifying control (20-95 %) with digital display of relative humidity - resolution of display 0.5 %, setting accuracy 1 % |
Humidity | humidity supply with distilled water from external tank by self-priming pump |
Humidity | active humidifying and de-humidifying adjustable from 20-95 % rh with digital display of relative humidity - resolution of display 0.5 %, setting accuracy 1 % |
Humidity | humidity supply with distilled water from external tank by self-priming pump |
Humidity | humidification by hot steam generator |
Controller | digital display of all set parameters, such a temperature, weekdays, time, CO2, humidity and set-up values - language to be chosen via set-up |
Controller | Electronic microprocessor temperature controller with auto-diagnostic system |
Timer | integrated timer for tempering profiles of up to 40 ramps each, each segment adjustable from 1 min. to 999 hrs. |
Timer | digital 7-day programme timer with real time clock, precise minute setting |
Temperature
resolution of display for setpoint values 0.1°C up to 99.9°C, 0.5°C from 100°C and for actual values 0.1°C (LED) | |
with humidity min. 8°C above ambient up to +90°C | |
without humidity min. 8°C above ambient up to +160°C |
Control technology
Calibration | three freely selectable temperature values |
---|
Ventilation
uniform atmosphere and temperature distribution owing to enclosed non-turbulent ventilation system in working chamber |
---|
Communication
Interface | USB-interface incl. Memmert software "Celsius" for programming and documentation |
---|---|
Documentation | integrated ring memory as data logger for GLP-conforming long-term documentation of all relevant parameters - 1024 kB |
Documentation | programme stored in case of power failure |
Documentation | parallel printer interface (incl. real time clock with date function) for all PCL3-compatible ink jet printers for GLP-conforming documentation |
Programming | chip-card control incl. 1 MEMoryCard XL with 32 kB storage capacity (max. 40 ramps) |
Safety
Temperature control | mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature |
---|---|
Temperature control | overtemperature monitor TWW, protection class 3.1 or adjustable temperature limiter TWB, protection class 2, selectable on display |
AutoSAFETY | additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature |
Autodiagnostic system | integral fault diagnostics for temperature and humidity control |
Alarm | with visual and acoustic alarm in case of over-/under temperature and underhumidity, open door and empty water tank |
Alarm | visual and acoustic |
Heating concept
large-area multi-function heating system on four sides with additional door and back heating to avoid condensation |
---|
Standard equipment
Scope of delivery | 2nd chip-card (STERICard) for sterilisation of working chamber with fixed values (4 hours/160°C) without removal of sensors |
---|---|
Scope of delivery | incl. works calibration certificate for +60°C |
Door | fully insulated stainless steel door with 2-point locking (compression door lock), lockable |
Door | inner glass door |
Housing | rear zinc-plated steel |
Interior | easy-to-clean interior,made of stainless steel,reinforced by deep drawn ribbing, material 1.4301 (ASTM 304), hermetically welded |
Internals | 2 perforated stainless steel shelves |
Stainless steel interior
Dimensions W x H x D in mm | w(A) x h(B) x d(C): 560 x 480 x 400 mm |
---|---|
Volume | 108 l |
Textured stainless steel casing
w(D) x h(E) x d(F): 710 x 778 x 550 mm |
Electrical data
Voltage Electrical load | 230 V, 50/60 Hz approx. 1000 W |
---|
Packing/shipping data
the appliances must be transported upright | |
---|---|
Customs tariff number | 8419 8998 |
Country of origin | Federal Republic of Germany |
WEEE-Reg.-No. | DE 66812464 |
Dimensions approx incl. carton | B x H x T: 830 x 1050 x 800 mm |
Net weight | approx. 70 kg |
Gross weight carton | approx. 95 kg |
Andalan Prima
CV. ANDALAN PRIMA SEJAHTERA
Supplier Laboratory Equipment, Glasware, Chemical, Electrical Test & Measuring Instrument
Jakarta
JL. SUMUR BATU RAYA No.1
skype : vitha.andalan2
Bekasi :
Muhtar tabrani Blok A-7 No 16
Telpon: 021-29253184,29253187,46560833, 46560834,
Mobile : 081280842187
Telp : +62-21-29253184, 29253187
Telp : +62-21-29253186
email : andalan1974@yahoo.com
skype : vitha.andalan2
MEDAN :
JL JAMIN GINTING NO 6 MEDAN
p : 061-8365706, 77804098
fax : 061-8365706
email : andalprima@ yahoo.co.id
AGENT FROM :
1. - JENCO INSTRUMENTS ( USA)
CONDUCTIVITY : POCKET - PORTABLE & BENCH tOP
DO METER : PORTABLE & BENCH TOP
PH METER : POCKET , TESTER , PORTABLE ( ANALOG / DIGITAL) & BENCHTOP ( ANALOG / DIGITAL) , INLINE - STATION
ION METER : POCKET , TESTER , PORTABLE & BENCHTOP, INLINE
2. - JEKEN ULTRASONIC CLEANER ( CHINA)
- Mekanical Mechanical control Timer
- Digital control Timer Heating Temperature control function
3.- MITECH INSTRUMENTS
- Ultrasonic Flow detector
- Coating thickness Meter
- Hardness Tester
Produk / Jasa Utama
Menjual:- HACH, MEMMERT, KYORITSU, INSTEK, MERCK, JENCO, BUCK SCIENTIFIC, ADWA, PYREX-IWAKI, PYREX USA, BRAND, WHATMAN, Aquadiagnostic, CARBOLITE, JENWAY, LOVIBON, SPECTRONIC, DAVIS WEATHER STATION, METONE, SHINAGAWA(DRY/ WET GAS METER
Disributor for Laboratory equipment, reagent, glassware, Test & Measuring Instrument.
Supplier and stockist for Laboratory Instrument and Equipment. - combustion Gas Analyzer
- Smokemeter