Spesifikasi Fluke 1621 Kit - Basic Earth Ground Tester
- 3-pole Fall-of-Potential earth testing for basic measurements
- 2-pole resistance measurements for added versatility
- Easily capture values with single-button operation
- Ensure accurate measurements with automatic ‘noise’ voltage detection
- Hazardous voltage warning offers increased user protection
- Clearly read and record data with a large, backlit display
- Hard carrying case
- Rugged holster and design for tough work environments
- Portable size allows for easy transportation
- Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting
- 600 V Cat II
General Specifications | ||
Measuring functions | 3-pole earth ground resistance, 2-pole AC resistance of a conductor, Interference voltage | |
Intrinsic error | Refers to the reference temperature range and is guaranteed for one year | |
Measuring rate | 2 measurements/second | |
Battery1 | One 9 volt alkaline (LR61) | |
Battery condition | LO-BAT is displayed if voltage drops below 6.5 V | |
Voltages | Between jacks H/C2 and E/C1 | 250 Veff maximum (effective voltage) |
Between jacks S/P2 and E/C1 | 250 Veff maximum | |
Climatic class | VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87) | |
Temperature performance2 | Working | -10°C to +50°C (+14°F to +122°F) |
Operating | 0°C to +35°C (+32°F to +95°F) | |
Storage | -20°C to +60°C (+68°F to +140°F) | |
Reference | +23°C ±2°C (+73°F ±4°F) | |
Temperature coefficient | ±0.1% of range per degree Kelvin | |
Safety | IEC/EN 61010-1, 600 V CAT II, pollution degree 2 | |
Dimensions | 113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster | |
Weight | 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3 | |
Electrical Specifications | ||
Maximum deviations | E1 Influence factor | Position |
E1 Deviation influence | 0% | |
E2 Influence factor | Supply voltage | |
E2 Deviation influence | 0% | |
E3 Influence factor | Temperature E3 | |
E3 Deviation influence | 2.3% | |
E4 Influence factor | Serial interference voltage (20 V) | |
E4 Deviation influence | 0.6% | |
E5 Influence factor | Probe- and auxiliary probe resistance | |
E5 Deviation influence | 10% | |
Test voltage | 3.7 kV | |
Protection type | IP 40; IEC/EN 60529 | |
Electromagnetic compatibility | Emission | IEC/EN 61326 Class B |
Immunity | IEC/EN 61326 Annex C | |
RE resistance measurement | Measuring method | Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5 |
Open circuit voltage | 23 to 24 V AC | |
Short circuit current | > 50 mA AC | |
Measuring frequency | 128 Hz | |
Maximum permissible overload | 250 Veff | |
Measuring time | 8 seconds (average from when START is pressed) | |
Limit input | Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient) | |
Automatic changeover of resolution | RH | < 7 kΩ |
Resolution | 0.01 Ω | |
RH | < 50 kΩ | |
Resolution | 0.1 Ω | |
RH | > 50 kΩ | |
Resolution | 1 Ω | |
Interference voltage display DC + AC | Vmax | 30 Veff |
Common mode rejection | > 80 dB at 50 Hz and 60 Hz | |
Ri | 680 kΩ | |
Measuring uncertainty | < 10% for pure AC and DC signals | |
Measuring Range | ||
0.15 Ω to 20 Ω | Resolution | 0.01 Ω |
Display range | 0 to 19.99 Ω | |
200 Ω | Resolution | 0.1 Ω |
Display range | 20 to 199.9 Ω | |
2 kΩ | Resolution | 1 Ω |
Display range | 200 to 1999 Ω | |
Intrinsic uncertainty | ±(6% of measured value + 5D) | |
Operating uncertainty IEC 615573 | ±(18% of measured value + 5D) |
Andalan Prima
CV. ANDALAN PRIMA SEJAHTERA
Supplier Laboratory Equipment, Glasware, Chemical, Electrical Test & Measuring Instrument
Jakarta
JL. SUMUR BATU RAYA No.1
skype : vitha.andalan2
Bekasi :
Muhtar tabrani Blok A-7 No 16
Telpon: 021-29253184,29253187,46560833, 46560834,
Mobile : 081280842187
Telp : +62-21-29253184, 29253187
Telp : +62-21-29253186
email : andalan1974@yahoo.com
skype : vitha.andalan2
MEDAN :
JL JAMIN GINTING NO 6 MEDAN
p : 061-8365706, 77804098
fax : 061-8365706
email : andalprima@ yahoo.co.id
AGENT FROM :
1. - JENCO INSTRUMENTS ( USA)
CONDUCTIVITY : POCKET - PORTABLE & BENCH tOP
DO METER : PORTABLE & BENCH TOP
PH METER : POCKET , TESTER , PORTABLE ( ANALOG / DIGITAL) & BENCHTOP ( ANALOG / DIGITAL) , INLINE - STATION
ION METER : POCKET , TESTER , PORTABLE & BENCHTOP, INLINE
2. - JEKEN ULTRASONIC CLEANER ( CHINA)
- Mekanical Mechanical control Timer
- Digital control Timer Heating Temperature control function
3.- MITECH INSTRUMENTS
- Ultrasonic Flow detector
- Coating thickness Meter
- Hardness Tester
Produk / Jasa Utama
Menjual:- HACH, MEMMERT, KYORITSU, INSTEK, MERCK, JENCO, BUCK SCIENTIFIC, ADWA, PYREX-IWAKI, PYREX USA, BRAND, WHATMAN, Aquadiagnostic, CARBOLITE, JENWAY, LOVIBON, SPECTRONIC, DAVIS WEATHER STATION, METONE, SHINAGAWA(DRY/ WET GAS METER
Disributor for Laboratory equipment, reagent, glassware, Test & Measuring Instrument.
Supplier and stockist for Laboratory Instrument and Equipment. - combustion Gas Analyzer
- Smokemeter