Spectrum Analyzers
Spesifikasi Spectrum Analyzers
|
· 3GHz Spectrum Analyzer
Featuring high performance, uncompromised design, and remote monitoring software, the GSP-830 3GHz Spectrum Analyzer is the latest evolution from GWInstek. The GSP-830 is one of the most advanced Spectrum Analyzer GWInstek has produced to date. The GSP-830 has an exceptional noise floor of -152dBm/Hz; combined with the optional GAP-802 preamplifier, the noise floor can reach a remarkable -172dBm/Hz. With a low noise floor, the GSP-830 is more than capable of finding limits; Trace Detection, combined with an easy-to-use interface, makes the GSP-830 an ideal solution for spectrum analysis. Using the Auto Sequence mode, advanced users can define their own macros in 10 Sequence sets. Repeat or Single run mode can be used to streamline repetitive tasks. PC connection is effortless and versatile supporting USB host/device, RS232C, VGA and GPIB (optional) for remote monitoring, control and analysis. |
FREQUENCY
|
|
Frequency Range
|
9kHz ~ 3GHz
|
Aging Rate
|
± 10ppm, 0~50°C, 5ppm/yr
|
Span Range
|
2kHz ~ 3GHz in 1-2-5 sequence, full span, zero span
|
Phase Noise
|
-80dBc/Hz @1GHz 20kHz offset typical
|
Sweep Time Range
|
50ms ~ 25.6s
|
RESOLUTION BANDWIDTH
|
|
RBW Range
|
3kHz, 30kHz, 300kHz, 4MHz
|
RBW Accuracy
|
15%
|
Video Bandwidth Range
|
10Hz ~ 1MHz in 1-3 steps
|
AMPLITUDE
|
|
Measurement Range
|
-103dBm ~ +20dBm: 1MHz ~ 15MHz, Ref.Level @ -30dBm
-117dBm ~ +20dBm: 15MHz ~ 1GHz, Ref.Level ≧-110dBm -114dBm ~ +20dBm: 1GHz ~ 3GHz, Ref.Level ≧-110dBm (Span = 50kHz, RBW = 3kHz) |
Overload Protection
|
Max. +30dBm, ±25VDC
|
Reference Level Range
|
-110dBm ~ +20dBm
|
Accuracy
|
±1dB @100MHz
|
Frequency Flatness
|
±1dB
|
Display Range Linearity
|
±1dB over 70dB
|
DYNAMIC RANGE
|
|
Average Noise Floor
|
<-135±1dBm/Hz: 1MHz ~ 15MHz, Ref.Level @ -30dBm
<-149dBm/Hz, typical -152dBm/Hz: 15MHz ~ 1GHz, Ref.Level ≧-110dBm <-146dBm/Hz, typical -149dBm/Hz: 1GHz ~ 3GHz, Ref.Level ≧-110dBm |
Third Inter-Modulation
|
<-70dBc RF Input @-40dBm, Ref.Level @-30dBm
|
Harmonic Distortion
|
<-60dBc RF Input <-40dBm Typical, Ref.Level @-30dBm
|
Non-Harmonic Spurious
|
<-93dBm, 1MHz ~ 15MHz, Ref.Level @-30dBm
<-107dBm ~ +20dBm: 15MHz ~ 1GHz, Ref.Level ≧-110dBm <-104dBm ~ +20dBm: 1GHz ~ 3GHz, Ref.Level ≧-110dBm (Span = 50kHz, RBW = 3kHz) |
GENERAL
|
|
Display
|
640 x 480 high resolution TFT color LCD
|
Split Windows
|
Active Window: Upper, Lower or Alternate (two simultaneously sweeping windows)
|
Markers
|
10 Markers for peaks: 5 normal-delta marker pairs
Functions: Delta, To Peak, To Minimum, Peak Track, Peak Table, Peak Sort |
Trace Detection
|
3 traces with Peak, Maximum hold, Freeze, Average, Trace math
|
Power Measurement
|
ACPR, OCBW, Channel Power, N dB and Phase Jitter
|
Autoset Function
|
Auto tuning the measurement result for observation
|
Trigger
|
Conditions: Video, External (Positive-going, +5V TTL external signal)
Mode: Normal, Single, Continuous |
Sequence
|
Automated test by user-defined macros without any remote controller, 10 Sequential macro set and 10 macros per each set, Variable delays and wait-to-go facilitate automated measurement, Do-sequence links and nests different sequence sets.
|
CONNECTORS
|
|
RF Input
|
N female, 50Ω nominal
RF input VSWR: <2:1, @0dBm Reference Level |
External Reference
|
Type: BNC female
|
Clock Input
|
1M, 1.544M, 2.048M, 5M, 10M, 10.24M, 13M, 15.36M, 15.4M, 19.2MHz
|
Reference Clock Output
|
Type: BNC female, 10MHz
|
DC Input (DC Power Operation)
|
Jack : 5.5mm, 12V
|
DC Output (for GAP-801)
|
Type: SMB Male, outputs +9V/100mA Max.
|
INTERFACE
|
|
RS-232C
|
Sub-D 9 pins female
|
USB Connector
|
USB Host/Device full speed supported
|
VGA Output
|
Front panel: Type A receptacle for USB flash devices
|
Option: GPIB Interface
|
Fully programmable with IEEE 488.2 compliance
|
POWER SOURCE
|
|
|
AC 100 ~ 240V, 50/60Hz
|
ACCESSORIES
|
|
|
User Manual x 1
Power Cord x 1 USB Cable (Type A plug to Type mini-B plug) x1 |
DIMENSIONS & WEIGHT
|
|
|
330(W) x 170(H) x 340(D) mm
Approx. 6kg |
User Manual x 1
Power Cord x 1
USB Cable (Type A plug to Type mini-B plug) x1
CV. ANDALAN PRIMA SEJAHTERA
Penjelasan Ringkas
CV. ANDALAN PRIMA SEJAHTERA
Supplier Laboratory Equipment, Glasware, Chemical, Electrical Test & Measuring Instrument
Jakarta
JL. SUMUR BATU RAYA No.1
skype : andalanprimasejahtera
Bekasi :
Muhtar tabrani Blok A-7 No 16
Telpon: 021-29253184,29253187,46560833, 46560834,
Mobile : 081382491575 / 081280842187 / 087882760369
Fak: 021-29253186
email : andalan_ prima@ yahoo.com / andalan1974@yahoo.com
skype : andalanprimasejahtera / cv.andalan.prima.sejahtera
MEDAN :
JL JAMIN GINTING NO 6 MEDAN
p : 061-8365706, 77804098
fax : 061-8365706
email : andalprima@ yahoo.co.id
AGENT FROM :
1. - JENCO INSTRUMENTS ( USA)
CONDUCTIVITY : POCKET - PORTABLE & BENCH tOP
DO METER : PORTABLE & BENCH TOP
PH METER : POCKET , TESTER , PORTABLE ( ANALOG / DIGITAL) & BENCHTOP ( ANALOG / DIGITAL) , INLINE - STATION
ION METER : POCKET , TESTER , PORTABLE & BENCHTOP, INLINE
2. - JEKEN ULTRASONIC CLEANER ( CHINA)
- Mekanical Mechanical control Timer
- Digital control Timer Heating Temperature control function
3.- MITECH INSTRUMENTS
- Ultrasonic Flow detector
- Coating thickness Meter
- Hardness Tester
Produk / Jasa Utama
Menjual:- HACH, MEMMERT, KYORITSU, INSTEK, MERCK, JENCO, BUCK SCIENTIFIC, ADWA, PYREX-IWAKI, PYREX USA, BRAND, WHATMAN, Aquadiagnostic, CARBOLITE, JENWAY, LOVIBON, SPECTRONIC, DAVIS WEATHER STATION, METONE, SHINAGAWA(DRY/ WET GAS METER
Disributor for Laboratory equipment, reagent, glassware, Test & Measuring Instrument.
Supplier and stockist for Laboratory Instrument and Equipment. - combustion Gas Analyzer
- Smokemeter