081362449440 Jual HI 9828-04/ 02 HANNA INSTRUMNET MULTI PARAMETER With GPS

Nego
Diperbarui: 20-04-2022 16:53
Brand: HANNA INSTRUMENT
Pembelian Minimal: 1 Unit
Pembelian Maksimal: 1 Unit
Pengiriman: 1 hari sejak pembayaran
Lokasi: DKI Jakarta - Jakarta Barat - Taman Sari
Detail 081362449440 Jual HI 9828-04/ 02 HANNA INSTRUMNET MULTI PARAMETER With GPS
Multi Parameter
 Type : HI 9828.
 Brand : HANNA INSTRUMNET
 

 SPEC IFICATIONS:
 pH      Range      0.00 to 14.00 pH
 Resolution      0.01 pH
 Accuracy      ± 0.02 pH
 mV of pH Input      Range      ± 600.0 mV
 Resolution      0.1 mV
 Accuracy      ± 0.5 mV
 ORP      Range      ± 2000.0 mV
 Resolution      0.1 mV
 Accuracy      ± 1.0 mV
 Dissolved
 Oxygen      Range      0.0 to 500.0% / 0.00 to 50.00 mg/ L
 Resolution      0.1% / 0.01 mg/ L
 Accuracy      0.0 to 300.0% : ± 1.5% of reading or ± 1.0% whichever is greater; 300.0 to 500.0% : ± 3% of reading; 0.00 to 30.00 mg/ L: ± 1.5% of reading or 0.10 mg/ L whichever is greater; 30.00 mg/ L to 50.00 mg/ L: ± 3% of reading
 Conductivity      Range      0.000 to 200.000 mS/ cm ( absolute EC up to 400 mS/ cm)
 Resolution      manual: 1 µ S/ cm; 0.001 mS/ cm; 0.01 mS/ cm; 0.1 mS/ cm; 1 mS/ cm; automatic: 1 µ S/ cm from 0 to 9999 µ S/ cm; 0.01 mS/ cm from 10.00 to 99.99 mS/ cm ; 0.1 mS/ cm from 100.0 to 400.0 mS/ cm; automatic mS/ cm: 0.001 mS/ cm from 0.000 to 9.999 mS/ cm; 0.01 mS/ cm from 10.00 to 99.99 mS/ cm; 0.1 mS/ cm from 100.0 to 400.0 mS/ cm
 Accuracy      ± 1% of reading or ± 1 µ S/ cm whichever is greater
 Resistivity      Range      0 to 999999 © • cm; 0 to 1000.0 k© • cm; 0 to 1.0000 M© • cm
 Resolution      dependent on resistivity reading
 TDS      Range      0 to 400000 mg/ L or ppm ( the maximum value depends on the TDS factor)
 Resolution      manual: 1 mg/ L ( ppm) ; 0.001 g/ L ( ppt) ; 0.01g/ L ( ppt) ; 0.1 g/ L ( ppt) ; 1 g/ L ( ppt) ; autorange scales: 1 mg/ L ( ppm) from 0 to 9999 mg/ L ( ppm) ; 0.01 g/ L ( ppt) from 10.00 to 99.99 g/ L ( ppt) ; 0.1 g/ L ( ppt) from 100.0 to 400.0 g/ L ( ppt) ; autorange g/ L ( ppt) scales: 0.001 g/ L ( ppt) from 0.000 to 9.999 g/ L ( ppt) ; 0.01 g/ L ( ppt) from 10.00 to 99.99 g/ L ( ppt) ; 0.1 g/ L ( ppt) from 100.0 to 400.0 g/ L ( ppt)
 Accuracy      ± 1% of reading or ± 1 mg/ L ( ppm) whichever is greater
 Salinity      Range      0.00 to 70.00 PSU ( Extended Practical Salinity Scale)
 Resolution      0.01 PSU
 Accuracy      ± 2% of reading or 0.01 PSU whichever is greater
 Seawater
 Specific
 Gravity      Range      0.0 to 50.0 Ã t, Ã 0, Ã 15
 Resolution      0.1 st, s0, s15
 Accuracy      ± 1 Ã t, Ã 0, Ã 15
 Atm. Pressure      Range      450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
 Resolution      0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
 Accuracy      ± 3 mmHg within ± 15° C from the calibration temperature
 Temperature      Range      -5.00 to 55.00° C; 23.00 to 131.00° F; 268.15 to 328.15K
 Resolution      0.01° C; 0.01° F; 0.01K
 Accuracy      ± 0.15° C; ± 0.27° F; ± 0.15K
 Calibration      pH      automatic one, two, or three points with five memorized standard buffers ( pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
 ORP      automatic at one custom point
 Conductivity      automatic one point with six memorized standards ( 84 µ S/ cm, 1413 µ S/ cm, 5.00 mS/ cm, 12.88 mS/ cm, 80.0 mS/ cm, 111.8 mS/ cm) or custom point
 DO      automatic one or two points at 0, 100% or one custom point
 Resistivity, TDS, Ã      based on conductivity or salinity calibration
 Salinity      one custom point
 Atm. Pressure,
 Temperature      automatic at one custom point
 Temperature
 Compensation           automatic from -5 to 55° C ( 23 to 131° F)
 Logging Memory           up to 60, 000 samples with 13 measurements each
 Logging Interval           1 second to 3 hours
 Computer
 Interface           USB ( with HI 929829 software)
 Waterproof
 Protection           meter IP67, probe IP68
 Environment           0 to 50° C ( 32 to 122° F) ; RH 100%
 Power Supply           1.5V alkaline C cells ( approximately 150 hours of continuous use without backlight) ( 4) / 1.2V rechargeable C cells ( approximately 70 hours of continuous use without backlight) ( 4)
 Dimensions
 Meter/ Probe           221 x 115 x 55 mm ( 8.7 x 4.5 x 2.2” ) / 270 x 46 mm DIA ( 10.6 x 1.8” DIA)
 Weight           meter: 750 g ( 26.5 oz.) ; probe: 750 g ( 26.5 oz.)
 
..
================
BINTANG INSTRUMENT
HP : 081362449440
Email : b081362449440@yahoo.com
=================

HANNA INSTRUMENT : 
 * Checker HC
 * Chemical Test Kits
 * pH Meters
 * pH/ ORP Meters
 * Ion Selective
 * pH/ ORP/ ISE/ Meters
 * Conductivity/ TDS
 * Digital Refractometers
 * Dissolved Oxygen
 * Multiparameter
 * Fertigation Systems
 * Titration Systems
 * Chemical Oxygen Demand
 * Photometers
 * Turbidity
 * Temperature
 * Relative Humidity
 * Magnetic Stirrers
 * Mini Panel Controllers
 * Process Instrumentation
 * Dosing Pumps
 * Lux Meters
 * Reagents
 * Solutions
 * Accessories
 * Hanna Sanitation Systems

BINTANG INSTRUMENT

DKI Jakarta - Jakarta Barat
Anggota Exclusive 3 Tahun
Scroll