081362449440 Jual Ammonia / amonia

Nego
Diperbarui: 20-04-2022 15:50
Brand: HANNA INSTRUMENT
Pembelian Minimal: 1 Unit
Pembelian Maksimal: 1 Unit
Pengiriman: 1 hari sejak pembayaran
Lokasi: DKI Jakarta - Jakarta Barat - Taman Sari
Detail 081362449440 Jual Ammonia / amonia

081362449440 Jual : Hanna HI-93700, HI -96715, HI 96733. Ammonia ( ISM , LR , MR, HR ) / AMonIA , Jual Ammonia Meter MI405 Low Parameter , Mi 407 Medium Parameter Martini Instrument Rumania..Ammonia Meter Indonesia Ready Stock Harga Rp...


AMMonIA METER,
1) Type : HI-93700 2)
Type : HI -96715 3)
Type : HI 96733 Ammonia ( ISM , LR , MR, HR ) / AMonIA ) . . .
Spesifications: . .
1) Hanna HI-93700 . .
Spesifications :
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms ( fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/ or civil pollutants. Ammonia is tested in lakes, rivers, potable water, boiler feed water, sewage, industrial and waste water. The HI-93700 measures from 0.00 to 3.00 mg/ L For the full product specification and accessories required please see the attached instruction manual. The HI-93700 is supplied complete with 2 sample cuvets, battery and instruction manual. Reagents NOT included. Product Specification Summary * Range: 0.00 to 3.00 mg/ L * Accuracy: + / -0.04mg/ L + / -4% of reading * Method: Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method. * Light source: LED ( Light Emitting Diode) * Auto Off: After 10 minutes of non-use * Power supply: Battery Type/ Life ( 1) 9V / approx. 40 hours of continuous use. * Dimensions: 180 x 83 x 46mm ( 7.1 x 3.3 x 1.8" ) * Weight: 290g ( 10 oz) . .

2) HI -96715 . Waterproof ISM for measuring Ammonia Medium range Type : HI96715
Specification :
* Range 0.00 to 9.99 mg/ L ( ppm) * Resolution 0.01 mg/ L ( ppm) * Accuracy ± 0.05 mg/ L ± 5% of reading @ 25° C * Light Detector Silicon Photocell with narrow band interference filter @ 466 nm * Light Source Light Emitting Diode * Environment 0 to 50° C ( 32 to 122° F) ; Max 95% RH non-condensing * Battery Type 9V * Auto Shut-off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder * Dimensions 192 x 104 x 69 mm ( 7.6 x 4.1 x 2.7" ) * Weight 360 g ( 12.7 oz.) * Method adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method * Reagent kit for 100 Test ( Ammonia MR ) Type : HI 93715-01 .

3. Ammonia ISM Type : HI 96733
Specification :
* Range 0.0 to 50.0 mg/ L ( ppm) * Resolution 0.1 mg/ L * Accuracy ± 0.5 mg/ L ± 5% of reading @ 25° C * Light Source Tungsten Lamp * Light Detection silicon photocell with narrow band interference filter @ 420 nm * Power Supply 9V battery * Environment 0 to 50° C ( 32 to 122° F) ; RH max 95% non-condensing * Dimensions 192 x 104 x 69 mm ( 7.6 x 4.1 x 2.7" ) * Weight 360 g ( 12.7 oz.) * Method adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method * Reagent kit for 100 test ( Ammonia HR ) Type : HI93733-01

BINTANG INSTRUMENT

DKI Jakarta - Jakarta Barat
Anggota Exclusive 3 Tahun
Scroll