Spesifikasi GW INSTEK GSP-9300 SPECTRUM ANALYZERS

 Features
  •  
    Frequency Range: 9kHz ~ 3GHz
  •  
    High Frequency Stability: 0.025ppm
  •  
    3dB RBW: 1Hz ~ 1MHz
  •  
    6dB EMI Filter: 200Hz, 9kHz, 120kHz, 1MHz
  •  
    Phase Noise: -88dBc/Hz @1GHz, 10kHz Offset
  •  
    Built-in Measurement Functions: 2FSK Analysis, AM/FM/ASK/FSK Demodulation & Analysis, EMC Pre-test, P1dB point, Harmonic, Channel Power, N-dB bandwidth, OCBW, ACPR, SEM, TOI, CNR, CTB, CSO, Noise Marker, Frequency Counter, Time Domain Power, Gated Sweep
  •  
    Built-in Spectrogram and Topographic Display Modes
  •  
    886MHz IF Output for User’s Extended Applications
  •  
    Remote Control Interface: LAN, USB, RS-232, GPIB (Optional)
  •  
    Built-in Preamplifier, 50dB Attenuator, and Sequence Function
  •  
    Optional 6GHz Power Sensor, Tracking Generator, Battery Back
Specification

Frequency     Frequency  Range 9 kHz to 3.0 GHz    Resolution 1 Hz  Frequency Reference Accuracy  ±[(period since last adjustment X aging rate) + stability over temperature + supply voltage stability     Aging Rate  ±2 ppm max.  1 year after last adjustment    Frequency Stability over Temperature  ±0.025 ppm  0 to 50 °C    Supply Voltage Stability  ±0.02 ppm   Frequency Readout Accuracy  Start, Stop, Center, Marker  ±(marker frequency indication X frequency reference accuracy + 10% x RBW +  frequency resolution*1)     Sweep points  601  Span >= 100 Hz      6 to 601  Span = 0 Hz  Marker Frequency Counter  Resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz     Accuracy  ±(marker frequency indication X frequency reference accuracy + counter resolution) 
RBW/Span >=0.02 ;
Mkr level to DNL>30 dB
Frequency Span  Range  0 Hz (zero span), 100 Hz to 3 GHz     Resolution  1 Hz     Accuracy ± frequency resolution*1   Phase Noise  Offset from Carrier  Fc =1 GHz; RBW = 1 kHz, VBW = 10 Hz;Average ≥ 40     10 kHz  <-88 dBc/Hz  Typical2    100 kHz  <-95 dBc/Hz  Typical   1 MHz  <-113 dBc/Hz  Typical  Resolution Bandwidth (RBW) Filter  Filter Bandwidth  1 Hz to 1 MHz in 1-3-10 sequence  -3dB bandwidth      200 Hz, 9 kHz, 120 kHz, 1 MHz  -6dB bandwidth    Accuracy  ± 8%, RBW = 1 MHz  Nominal3      ± 5%, RBW < 1 MHz  Nominal    Shape Factor  < 4.5:1  Normal Bandwidth ratio: -60dB:-3dB  Video Bandwidth (VBW) Filter  Filter Bandwidth  1 Hz to 1 MHz in 1-3-10 sequence  -3dB bandwidth  [1] Frequency Resolution = Span/(Sweep points - 1)
 
[2] Typical specifications in this datasheet mean that the performance can be exhibited in 80% of the units with a 95% confidence level over the temperature range 20 to 30 °C. They are not covered by the product warranty.
 
[3] Nominal values indicate expected performance. They are not covered by the product warranty.   
  Amplitude     Amplitude Range  Measurement Range    100 kHz to 1 MHz Displayed Average Noise Level (DANL) to 18 dBm      1 MHz to 10 MHz  DANL to 21 dBm      10 MHz to 3 GHz  DANL to 30 dBm  Attenuator  Input Attenuator Range  0 to 50 dB, in 1 dB step  Auto or manual setup  Maximum Safe Input Level  Average Total Power  <= 33 dBm  Input attenuator 
≥10 dB    DC Voltage  ± 50 V   1 dB Gain Compression  Total Power at 1st Mixer  > 0 dBm  Typical;Fc ≥50 MHz; preamp. off    Total Power at the Preamp   > -22 dBm      mixer power level (dBm)= input power (dBm)-attenuation (dB)   Displayed Average Noise Level (DANL)*4  Preamp off  0 dB attenuation; RF Input is terminated with a 50 Ohm load. RBW 10 Hz; VBW 10 Hz; span 500 Hz; reference level =  -60dBm; trace average ≥ 40       9 kHz to 100 kHz, < -93 dBm  Nominal         100 kHz to 1 MHz, < -90 dBm - 3 x (f/100 kHz) dB      1 MHz to 10 MHz, < -122 dBm      10 MHz to 3 GHz, < -122 dBm    Preamp on  0 dB attenuation; RF Input is terminated with a 50 Ohm load. RBW 10 Hz; VBW 10Hz; span 500 Hz;  reference level =  -60dBm; trace average ≥ 40       100 kHz to 1 MHz, < -108 dBm - 3 x (f/100 kHz) dB  Nominal        1 MHz to 10 MHz, < -142 dBm      10 MHz to 3 GHz,  < -142 dBm + 3 x (f/1 GHz) dB   [4] DANL spec shall exclude the Spurious Response   
  Level Display Range  Scales  Log, Linear    Units  dBm, dBmV, dBuV, V, W     Marker Level Readout  0.01 dB  Log scale      0.01 % of reference level  Linear scale    Level Display Modes  Trace, Topographic, Spectrogram  Single / split Windows    Number of Traces   4    Detector  Positive-peak, negative-peak, sample,  normal, RMS(not Video)  Can be setup for each trace separately    Trace Functions  Clear & Write, Max/Min Hold, View, Blank, Average   Absolute Amplitude Accuracy  Absolute Point  Center=160 MHz ; RBW 10 kHz; VBW 1 kHz; span 100 kHz; log scale;  1 dB/div; peak detector; 20 to 30°C; signal 0 dBm     Preamp off  ± 0.3 dB  Ref level 0 dBm; 10 dB RF attenuation    Preamp on  ± 0.4 dB  Ref level -30 dBm; 0 dB RF attenuation  Frequency Response  Preamp off  Attenuation: 10 dB; Reference: 160 MHz; 20 to 30°C       100 kHz to 2.0 GHz  ± 0.5 dB      2.0GHz to 3.0 GHz  ± 0.7 dB    Preamp on  Attenuation: 0 dB; Reference: 160 MHz; 20 to 30°C       1 MHz to 2.0 GHz  ± 0.6 dB      2.0GHz to 3.0 GHz  ± 0.8 dB  Attenuation Switching Uncertainty  Attenuator setting  0 to 50 dB in 1 dB step     Uncertainty  ± 0.25 dB  reference: 160 MHz, 10dB attenuation  RBW Filter Switching Uncertainty  1 Hz to 1 MHz  ± 0.25 dB  reference : 10 kHz RBW  Level Measurement Uncertainty  Overall Amplitude Accuracy  ± 1.5 dB  20 to 30°C; frequency > 1 MHz; Signal input 0 to -50 dBm; Reference level  0 to -50 dBm; 
Input attenuation 10 dB;  
RBW  1 kHz; VBW 1 kHz; after cal; Preamp Off 
    ± 0.5 dB  Typical  Spurious Response  Second Harmonic Intercept  Preamp off; signal input -30dBm; 0 dB attenuation       +35 dBm  Typical; 10 MHz < fc < 775 MHz      +60 dBm  Typical; 775 MHz ≤ fc < 1.5 GHz    Third-order Intercept  Preamp off; signal input -30dBm; 0 dB attenuation       > 1dBm  300 MHz to 3 GHz    Input Related Spurious  < -60 dBc  Input signal level -30 dBm, Att. mode, Att=0 dB; 20-30 degree C   Residual Response (inherent)  <-90 dBm  Input terminated; 0 dB attenuation; Preamp off  Sweep    Sweep Time  Range  22ms to 1000s  Span >= 100 Hz     50us to 1000s  Span = 0 Hz; Min Resolution = 10 us    Sweep Mode  Continuous; Single     Trigger Source  Free run; Video; External     Trigger Slope  Positive or negative edge   RF Preamplifier      Frequency Range  1 MHz to 3 GHz     Gain  18 dB  Nominal
(installed as standard)  Front Panel Input/Output    RF Input  Connector Type  N-type female     Impedance  50 ohm, nominal     VSWR  <1.6 :1  300 kHz to 3 GHz; Input attenuator ≥ 10 dB  Power for Option  Connector Type  SMB male     Voltage/Current  DC +7V / 500 mA max  With short-circuit protection  USB Host  Connector Type  A plug      Protocol  Version 2.0  Supports Full/High/Low speed  MicroSD Socket  Protocol  SD 1.1      Supported Cards  MicroSD, MicroSDHC  Up to 32GB capacity  Rear Panel Input/Output    Reference Output  Connector Type  BNC female     Output Frequency  10 MHz     Output Amplitude  3.3V CMOS     Output Impedance  50 ohm   Reference Input  Connector Type  BNC female     Input Reference Frequency  10 MHz     Input Amplitude  -5 dBm to +10 dBm     Frequency Lock Range  Within ± 5 ppm of the input reference frequency   Alarm Output  Connector Type  BNC female; Open-collector   Trigger Input/ Gated Sweep Input  Connector Type  BNC female     Input Amplitude  3.3V CMOS     Switch  Auto selection by function   LAN TCP/IP Interface  Connector Type  RJ-45     Base  10Base-T; 100Base-Tx; Auto-MDIX   USB Device  Connector Type  B plug  For remote control only; supports USB TMC    Protocol  Version 2.0  Supports Full/High speed  IF Output  Connector Type  SMA female     Impedance  50 ohm  Nominal    IF Frequency  886 MHz  Nominal    Output level  -25 dBm  10 dB attenuation; RF input: 0 dBm @ 1 GHz;  Earphone Output  Connector Type  DVI-I ( integrated analog and digital) , Single Link  Compatible with VGA or HDMI standard  through adapter  RS232 Interface  Connector Type  D-sub 9-pin female  Tx,Rx,RTS,CTS  GPIB Interface (Optional)  Connector Type  IEEE-488 bus connector   AC Power Input  Power Source  AC 100 V to 240 V, 50 / 60 Hz  Auto range selection  Battery Pack (Optional)  Battery pack  6 cells, Li-Ion rechargeable, 3S2P  With UN38.3 Certification    Voltage  DC 10.8 V     Capacity  5200 mAh / 56Wh   General      Internal Data storage  16 MB nominal     Power Consumption  <65 W     Warm-up Time  < 30 minutes     Temperature Range  +5 °C to +45 °C  Operating     -20 °C to + 70 °C  Storage    Weight  4.5 kg (9.9 lb)  Inc. all options (Basic+TG+GPIB+Battery)    Dimensions  210 x 350 x 100 (mm)  Approximately      8.3 x  13.8 x 3.9 (in)    Tracking Generator*5 (Optional)      Frequency Range  100 kHz to 3 GHz     Output Power  -50 dBm to 0 dBm in 0.5 dB steps     Absolute Accuracy  ± 0.5 dB  @160 MHz, -10 dBm, Source attenuation 10 dB, 20 to 30°C    Output Flatness  Referenced to 160 MHz, -10 dBm       100 kHz to 2 GHz  ± 1.5 dB      2 GHz to 3 GHz  ± 2.0 dB    Output Level Switching Uncertainty  ± 0.8 dB  Referenced to -10 dBm    Harmonics  < -30 dBc  Typical, output level = -10 dBm    Reverse Power  +30 dBm max.     Connector type  N-type female     Impedance  50 ohm  Nominal    Output VSWR  < 1.6:1  300 kHz to 3 GHz, source attenuation ≥ 12 dB  [5] The minimum RBW filter is 10 kHz when the TG output is ON.   
  USB Power Sensor (Optional)      Type  Average power sensor  Model: PWS-06    Interface to Meter  USB cable to GSP930 Front-Panel USB Host     Connector Type  N-type male, 50 ohm nominal     Input VSWR  1.1: 1  Typical      1.3: 1  Max    Input Frequency  1 to 6200 MHz     Sensing Level  -32 to +20 dBm     Max. Input Damage Power  <= 27 dBm     Power Measurement Uncertainty 
@ 25 °C 
-30 dBm to +5 dBm:       1 MHz to 3GHz: ±0.10 dB typical  ±0.30 dB max.      3 GHz to 6 GHz: ±0.15 dB typical ±0.30 dB max.      +5 dBm to +12 dBm:       1 MHz to 3GHz: ±0.15 dB typical  ±0.30 dB max.      3 GHz to 6 GHz: ±0.15 dB typical  ±0.30 dB max.      +12 dBm to +20 dBm:       1 MHz to 3GHz: ±0.20 dB typical  ±0.40 dB max.      3 GHz to 6 GHz: ±0.20 dB typical  ±0.40 dB max.    Power Measurement Uncertainty 
@ 0 to 25 °C 
-30 dBm to +5 dBm:       1 MHz to 3GHz: ±0.25 dB typical       3 GHz to 6 GHz: ±0.25 dB typical       +5 dBm to +12 dBm:       1 MHz to 3GHz: ±0.20 dB typical       3 GHz to 6 GHz: ±0.20 dB typical       +12 dBm to +20 dBm:       1 MHz to 3GHz: ±0.35 dB typical       3 GHz to 6 GHz: ±0.30 dB typical     Linearity @ 25 °C  ±3 %     Measurement Speed  100 ms for Low Noise Mode  Typical      30 ms for Fast Mode   
Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


Rp. 123 / Unit
CV. KARYA BAKTI NUSANTARA
CALL
PT. SITOHO LAMSUKSES - INDONESIA
CALL
PT. SITOHO LAMSUKSES - INDONESIA
CALL
PT. SITOHO LAMSUKSES - INDONESIA
CALL
PT. SITOHO LAMSUKSES - INDONESIA
CALL
PT. SITOHO LAMSUKSES - INDONESIA