FREQUENCY | |
Frequency Range | 9kHz ~ 3GHz |
Aging Rate | ± 10ppm, 0~50°C, 5ppm/yr |
Span Range | 2kHz ~ 3GHz in 1-2-5 sequence, full span, zero span |
Phase Noise | -80dBc/Hz @1GHz 20kHz offset typical |
Sweep Time Range | 50ms ~ 25.6s |
RESOLUTION BANDWIDTH | |
RBW Range | 3kHz, 30kHz, 300kHz, 4MHz |
RBW Accuracy | 15% |
Video Bandwidth Range | 10Hz ~ 1MHz in 1-3 steps |
AMPLITUDE | |
Measurement Range | -103dBm ~ +20dBm: 1MHz ~ 15MHz, Ref.Level @ -30dBm -117dBm ~ +20dBm: 15MHz ~ 1GHz, Ref.Level ≧-110dBm -114dBm ~ +20dBm: 1GHz ~ 3GHz, Ref.Level ≧-110dBm (Span = 50kHz, RBW = 3kHz) |
Overload Protection | Max. +30dBm, ±25VDC |
Reference Level Range | -110dBm ~ +20dBm |
Accuracy | ±1dB @100MHz |
Frequency Flatness | ±1dB |
Display Range Linearity | ±1dB over 70dB |
DYNAMIC RANGE | |
Average Noise Floor | <-135±1dBm/Hz: 1MHz ~ 15MHz, Ref.Level @ -30dBm <-149dBm/Hz, typical -152dBm/Hz: 15MHz ~ 1GHz, Ref.Level ≧-110dBm <-146dBm/Hz, typical -149dBm/Hz: 1GHz ~ 3GHz, Ref.Level ≧-110dBm |
Third Inter-Modulation | <-70dBc RF Input @-40dBm, Ref.Level @-30dBm |
Harmonic Distortion | <-60dBc RF Input <-40dBm Typical, Ref.Level @-30dBm |
Non-Harmonic Spurious | <-93dBm, 1MHz ~ 15MHz, Ref.Level @-30dBm <-107dBm ~ +20dBm: 15MHz ~ 1GHz, Ref.Level ≧-110dBm <-104dBm ~ +20dBm: 1GHz ~ 3GHz, Ref.Level ≧-110dBm (Span = 50kHz, RBW = 3kHz) |
GENERAL | |
Display | 640 x 480 high resolution TFT color LCD |
Split Windows | Active Window: Upper, Lower or Alternate (two simultaneously sweeping windows) |
Markers | 10 Markers for peaks: 5 normal-delta marker pairs Functions: Delta, To Peak, To Minimum, Peak Track, Peak Table, Peak Sort |
Trace Detection | 3 traces with Peak, Maximum hold, Freeze, Average, Trace math |
Power Measurement | ACPR, OCBW, Channel Power, N dB and Phase Jitter |
Autoset Function | Auto tuning the measurement result for observation |
Trigger | Conditions: Video, External (Positive-going, +5V TTL external signal) Mode: Normal, Single, Continuous |
Sequence | Automated test by user-defined macros without any remote controller, 10 Sequential macro set and 10 macros per each set, Variable delays and wait-to-go facilitate automated measurement, Do-sequence links and nests different sequence sets. |
CONNECTORS | |
RF Input |
N female, 50Ω nominal RF input VSWR: <2:1, @0dBm Reference Level |
External Reference | Type: BNC female |
Clock Input | 1M, 1.544M, 2.048M, 5M, 10M, 10.24M, 13M, 15.36M, 15.4M, 19.2MHz |
Reference Clock Output | Type: BNC female, 10MHz |
DC Input (DC Power Operation) | Jack : 5.5mm, 12V |
DC Output (for GAP-801) | Type: SMB Male, outputs +9V/100mA Max. |
INTERFACE | |
RS-232C | Sub-D 9 pins female |
USB Connector | USB Host/Device full speed supported |
VGA Output | Front panel: Type A receptacle for USB flash devices |
Option: GPIB Interface | Fully programmable with IEEE 488.2 compliance |
POWER SOURCE | |
AC 100 ~ 240V, 50/60Hz | |
ACCESSORIES | |
User Manual x 1 Power Cord x 1 USB Cable (Type A plug to Type mini-B plug) x1 |
|
DIMENSIONS & WEIGHT | |
330(W) x 170(H) x 340(D) mm Approx. 6kg |
Opt. 01 | Tracking Generator | - Frequency Range: 9k~3GHz - Amplitude Range: -50dBm~0dBm - Amplitude Accuracy: ±1dB@100MHz, 0dBm - Amplitude Flatness: ±1dB@0dBm - Harmonics: <-30dBc typical - Reverse Power: +30dBm - Impedance: Type: N female, 50Ω nominal - RF output VSWR: < 2:1 |
Opt. 02 | Battery pack | * 11.1V Li-Ion battery pack *2 |
Opt. 03 | ± 1ppm Stability | * ±1ppm, 0~50 °C , ±1ppm/yr |
Opt. 04 | 300Hz RBW | * RBW 300Hz, 3dB bandwidth, RBW Accuracy: 20% |
Opt. 05 | EMI Filter 9kHz & 120kHz RBW(*) | * RBW selections: 9kHz & 120kHz, 6dB bandwidth, Accuracy: 15% |
Opt. 06 | 10kHz & 100kHz RBW (*) | * RBW selections: 10kHz & 100kHz, 3dB bandwidth, Accuracy: 15% |
Opt. 07 | Demodulator (*) | * Demodulation: AM/ FM * Output: Internal speaker, 3.5mm stereo jack wired for mono operation * RBW selection: 10kHz & 100kHz, 3dB bandwidth, Accuracy: 15% |
Opt. 08 | GPIB Interface | * IEEE 488 bus |
Note: 1. (*) Only one option can be selection between Opt. 05, 06, 07 2. All options are factory-installed except opt.02. |
OPTIONAL ACCESSORIES | |
ATA-001 | BNC Antenna (An additional ADP-001 is needed for fitting GSP spectrum analyzers) |
ATA-002 | Near Field Probe (An additional ADP-001 & GTL-110 is needed for fitting GSP spectrum analyzers) |
GAP-801 | Preamplifier Preamplifier with 10dB(typical), gain 9kHz ~ 6GHz |
GAP-802 | Preamplifier Preamplifier with 20dB(typical), gain 9kHz ~ 3GHz |
RLB-001 | Return Loss Bridge RLB Frequency Range 10MHz ~ 1GHz |
GTP-3000 | Passive touch Probe Set PR-03: Passive touch probe, SMA(F) ADP-002: Adaptor, SMA(J/F) ~ N(P/M) GTL-303: RF Cable Assembly, SMA(P/M), 600mm |
GKT-001 | General Kit set ADP-002: adaptor, SMA(J/F) ~ N(P/M) x 2 ATN-100: 10dB attenuator, N(J/F) ~ N(P/M) x 1 GTL-303: RF cable assembly(SMA(P/M),RD316,600mm)x2 GSC-002: Kit box x 1 |
GKT-002 | CATV Kit set ADP-001: adaptor, BNC(J/F) ~ N(P/M) x 2 ADP-101: adaptor, BNC(J/F)75Ω ~ BNC(P/M)50Ωx 2 GTL-304: RF cable assembly(RG223,N(P/M)-N(J/F),300mm)x2 GSC-003: Kit box x 1 |
GKT-003 | RLB Kit set GAK-001: termination 50 , N(P/M) x 1 GAK-002: Cap with chain, N(P/M) x 1 GTL-302: RF cable assembly(RG223,N(P/M),300mm)x2 GSC-004: Kit box x 1 |
GKT-006 | EMI Probe Kit set ANT-01: 6cm Loop, H-Field Probe x 1 ANT-02: 3cm Loop, H-Field Probe x 1 ANT-03 6mm Stub tip, E- Field Probe x 1 PR-03: Touch Passive Probe x 1 ADP-02: N(P/M)~SMA(J/F) Adapter x 1 ADP-01: N(P/M)~BNC(J/F) Adapter x 1 Test Lead: BNC(P/M)~BNC(P/M) RF Cable x 1 Test Lead: SMA(P/M)~SMA(P/M) RF Cable x 1 |
GRA-404 | Rack Adapter Panel Rack Mounting (19", 4U) |
GSC-001 | Soft Carrying Case |
GTL-301 | RF Cable RG 223 N(P/M), 1000mm |
GTL-401 | DC Power Cord DC power cord with DC Jack and lighter plug, Current 5A |
ANDALAN PRIMA SEJAHTERA
Kami CV ANDALAN PRIMA SEJAHTERA.
Alamat
Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara
Phone : 021 - 29253187, 29253184, Fax : 021-29253186
Email : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com
Website : www.andalanprimasejahtera.com
Yang berdiri sejak tahun 2005 adalah distributor laboratory equipment, reagent, measuring and test instrument
Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air
Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.