Fluke 125/S ScopeMeter® Oscilloscopes with SCC120 kit
Spesifikasi Fluke 125/S ScopeMeter® Oscilloscopes with SCC120 kit
Specifications | |
Oscilloscope bandwidth | 40 MHz |
Dual input true RMS meter | VDC, VAC, VAC + VDC, Ohms,Continuity, Diode-test Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset |
TrendPlot recording | Automatic vertical scaling and time compression Display the actual, MIN, MAX and AVG reading |
Cursors | Fluke 125/124: ΔT, 1/ΔT, V, ΔV, rise- and fall time |
Sample rate | 2.5 GS/s repetitive sampling 25 MS/s single shot sampling |
Inputs and digitizers | 2 |
Timebase range | 20 ns - 1 min/div |
Input sensitivity | 5 mV - 500 V/div |
Trigger types | Connect-and-View™, Free Run, Single Shot, Edge, Video, External |
Glitch capture | 40 ns |
Scope measurements | Automatic measurements: 26 (all instruments) On top, Fluke 125 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems |
Harmonics mode | Capability to analyze the harmonics contents of power signals (see Harmonics Mode Section below for details) |
Maximum record length | 512 min/max pts per input |
Memory | 20 screens and setups |
Additional Power Measurement Capabilities | |
Measurement Types | Watt, VA VAR, Power Factor (PF) |
Power Configuration | Single phase or balanced three-phase (delta-configuration) mains supply |
Voltage Measurement | Channel A; using STL120, voltage probe or direct input |
Current Measurement | Channel B, using i400s (included) or other compatible current clamp |
Current clamp or shunt sensitivity | 0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/mA and 400 mV/A |
Harmonics mode | |
Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic | |
Analyzed waveform | Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated |
Harmonics frequency range | DC up to 33rd harmonic (for fundamental up to 60 Hz); DC up to 24th harmonic (for fundamental up to 400 Hz) |
Display | Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental |
Measurements | Relative amplitude of individual harmonics; THD in %r or %f |
Bus Health Test Functions | |
Bus health test | Verifies the electrical parameters of industrial bus systems using automatic measurement and analysis functions. Next to that, an Eyepattern mode is provided for visual inspection of signal quality. |
Parameter classification | Default values:
Limits values, as a default, are based on industry standard for the selected bus type or may be set by the user. |
Bus systems supported | AS-i (EN50295, 166 kb/s); CAN-bus (ISO-11898, up to 1 Mb/s); Interbus S (EIA-485, 500 kb/s); ControlNet (61158 type 2, 5Mb/s); Modbus (EIA-232 up to 115 kb/s and EIA-485 up to 10 Mb/s); Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s); Profibus DP (EIA-485 up to 10 Mb/s); Profibus PA (61158 type 1, 31.25 kb/s); Ethernet 10Base2 (coaxial); Ethernet 10BaseT (UTP, 10 Mb/s); RS-232 (EIA-232, up to 115 kb/s); RS-485 (EIA-485, up to 10 Mb/s); User defined single wire or balanced system |
Modes | Waveform Parameter Analysis With Automatic Read-out And Parameter:
|
Measured parameters (where applicable) |
Baud rate, Risetime, Fall time, High level, Low level, Bias voltage level, Signal amplitude, Distortion, Jitter |
Eyepattern display mode | Gives waveform display of bus signals with display persistence Timebase and attenuator settings may be altered by the user |
Environmental Specifications | |
Operating temperature | 0°C to 50°C |
Storage temperature | -20°C to +60°C |
Operating Altitude | 3,000 m |
Safety Specifications | |
Electrical safety | 600 V CAT III (EN61010-1) |
Mechanical And General Specifications | |
Size | 232 x 115 x 50 mm |
Weight | 1.2 kg |
Warranty | 3-years on main instrument 1-year on accessories |
Battery life | 7 hrs using NiMH |
RS232/USB unterface | Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC |
Andalan Prima
CV. ANDALAN PRIMA SEJAHTERA
Supplier Laboratory Equipment, Glasware, Chemical, Electrical Test & Measuring Instrument
Jakarta
JL. SUMUR BATU RAYA No.1
skype : vitha.andalan2
Bekasi :
Muhtar tabrani Blok A-7 No 16
Telpon: 021-29253184,29253187,46560833, 46560834,
Mobile : 081280842187
Telp : +62-21-29253184, 29253187
Telp : +62-21-29253186
email : andalan1974@yahoo.com
skype : vitha.andalan2
MEDAN :
JL JAMIN GINTING NO 6 MEDAN
p : 061-8365706, 77804098
fax : 061-8365706
email : andalprima@ yahoo.co.id
AGENT FROM :
1. - JENCO INSTRUMENTS ( USA)
CONDUCTIVITY : POCKET - PORTABLE & BENCH tOP
DO METER : PORTABLE & BENCH TOP
PH METER : POCKET , TESTER , PORTABLE ( ANALOG / DIGITAL) & BENCHTOP ( ANALOG / DIGITAL) , INLINE - STATION
ION METER : POCKET , TESTER , PORTABLE & BENCHTOP, INLINE
2. - JEKEN ULTRASONIC CLEANER ( CHINA)
- Mekanical Mechanical control Timer
- Digital control Timer Heating Temperature control function
3.- MITECH INSTRUMENTS
- Ultrasonic Flow detector
- Coating thickness Meter
- Hardness Tester
Produk / Jasa Utama
Menjual:- HACH, MEMMERT, KYORITSU, INSTEK, MERCK, JENCO, BUCK SCIENTIFIC, ADWA, PYREX-IWAKI, PYREX USA, BRAND, WHATMAN, Aquadiagnostic, CARBOLITE, JENWAY, LOVIBON, SPECTRONIC, DAVIS WEATHER STATION, METONE, SHINAGAWA(DRY/ WET GAS METER
Disributor for Laboratory equipment, reagent, glassware, Test & Measuring Instrument.
Supplier and stockist for Laboratory Instrument and Equipment. - combustion Gas Analyzer
- Smokemeter