081362449440 Jual Petroleum Quality Analyzer SX-300 Jual SHATOX SX-300 Brochure PDF Harga Rp...

Update Terakhir
21-05-2024
Dilihat Sebanyak
75 kali
Lokasi
DKI Jakarta - Jakarta Barat - Taman Sari
Harga
Kontak Kami
Bagikan
+ Penawaran

Spesifikasi 081362449440 Jual Petroleum Quality Analyzer SX-300 Jual SHATOX SX-300 Brochure PDF Harga Rp...

 

BINTANG INSTRUMENT : HP /WA :  081362449440 , eMail : b081362449440@yahoo.com ( Mr Jonathan )

Petroleum Quality Analyzer
Type : SX-300
Brand : SHATOX
Origin : Rusia


SHATOX SX-300 Petroleum Quality Analyzer

New oil products grade analyzer is manufactured on the basis of advanced high precision microprocessor. The instrument can be used together with a PC or laptop through USB interface. Analyzer uses automatic computer-based calibration, saving measured data in the instrument memory with analysis date and time followed by their transfer to the PC (in Microsoft Excel or txt format). The instrument has easy of control attrition and aggressive environments resistive 8-key antiglare keyboard (made in Germany).

Analyzer SX-300 has a distinctive characteristic, an additional sensor, which measures oil products volume resistivity with high precision. Therefore, fuel analysis may be based on two values, which allows measuring octane number of petrols with ferriferous (ferrocene), nickel and manganese additives, and to determine other substances content.
By using this measurement principle the instrument allows to determine:

  • contamination content in oil products;
  • pour-point depressants content in diesel fuel;
  • engine oil base number;
  • oil products volume resistivity.

When determining petrol breakdown time, the petrol brand is selected in the instrument. The instrument switches to corresponding operating mode. Oxidative stability determination complies with GOST 4039-88 (ASTM D 525)

Motor oil brand identification is based on the permittivity determination principle. Genuine motor oils have certain value for this characteristic. Leading manufacturers’ oil brands are included into the instrument database (the database can be renewed or changed).

Water-in-oil percentage of oil and oil products is determined in compliance with GOST 14203-69 (Dielectric humidity measuring method). This allows using the instrument as a dielectric moisture indicator for oil products.

The instrument uses the timer microchip, which allows storing measurement results with analysis date and time. These data can also be transmitted to the computer.

New computer software is included into the set.
- measurement results are reflected on computer screen in convenient form;

 

Instrument capabilities:

  • Determining octane numbers for motor gasoline. Complies with ASTM D 2699-86, ASTM D 2700-86.

  • Determining cetane numbers for diesel fuel. Complies with ASTM D 4737-03, ASTM D 613, EN ISO 5165.

  • Cold filter plugging point and diesel type.

  • Content of antiknock ferrous octane boosters.

  • Content of water in diesel fuel.

  • Content of kerosine in diesel fuel.

  • Content of lube in gasoline.

  • Petrol breakdown time (oxidative stability). Complies with ASTM D 525.

  • Loss angle tangent of transformer, machine and engine oil.

  • Level of engine oil clarity.

  • Engine oil grade.

  • Engine oil base number.

  • Dielectric permeability of oil products.

  • Oil products volume resistivity.

  • Determining the mechanical impurities content in oil products.

Technical characteristics

Parameter description   Measurement units  Value
Measured petrols octane numbers range

ON

40–135
Acceptable limit of octane number measurement basic error, max

ON

± 0.5
Limit of acceptable difference between parallel octane number measurements, max ON ± 0.2
The determination range of antiknock additives content in petrols

%

0.1-15

Acceptable basic error limit of antiknock additives content determination in petrols % 0.1
Petrol oxidation breakdown time measurement range min. 50-2400
Acceptable basic error limit of petrol oxidation breakdown time % 10
Petrol quality determination mode basing on volume resistivity Om 10 6-10 14
Acceptable basic error limit of volume resistivity measurements % 3
Cetane numbers measurement range CN 20–100
Acceptable basic error limit of cetane numbers, max CN ±1.0
Acceptable difference limit between cetane numbers parallel measurements, max CN ± 0.5
Acceptable error limit when determining diesel-fuel pour point o ± 5
Kerosine content determination range in diesel fuels % 0-95
Acceptable basic error limit when determining kerosene content in diesel fuels % 3
Motor oils clarity level measurement range % 95-100
Acceptable error limit of motor oils clarity level measurement % 0.1
Acceptable difference limit between motor oils clarity parallel measurements % 0.01
Fuel and lubricants dielectric permeability measurement range units 1–5
Acceptable error limit of dielectric permeability measurement, max units 0.001
Acceptable difference limit between Fuel and lubricants dielectric permeability parallel measurements, max units 0.001
Oils base number determination range units 0-24
Acceptable basic error limit when determining oils basic number BN units 1
Motor oils manufacturer and brand determination Manufacturer -
Circuit-breaker oils (dielectrics) breakdown voltage measurement range kV 5–100
Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max kV 1
Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max kV 0.2
Measurement range of circuit-breaker oils loss angle tangen % 0.01–5
Acceptable error limit of circuit-breaker oils loss angle tangent, max % 0.01
Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max units 0.001
Determination range for mechanical impurities content in oil products % 97-100
Acceptable basic error limit when determining mechanical impurities content in oil products % 0.01
Water-in-oil content determination range for oil products % 0-4
Acceptable basic error limit when determining water-in-oil content of oil products % 0.01
     
Measurement time s 1–5
Insufficient power supply indication operation threshold V 5.4
Instrument useful life years 6
Overall dimensions of:    
     electronic module mm 211x100x45
     sensor #1 and #2: mm 60х100
     Instrument mass with one sensor/two sensors gr 850

Delivery package:

  • Electronic computing module

  • Detector #1

  • Detector #2

  • Sample imitator for detector #1

  • mini-USB cable

  • Operations manual

  • Warranty certificate

  • Tool canvas bag

Tampilkan Lebih Banyak

BINTANG INSTRUMENT

Kami Menjual.
Perusahaan kami bergerak sebagai Distributor berbagai macam Jasa Pengadaan Barang / Supplier Oil & Gas Equipment & safety ,  M & E Equipment, serta sebagai spesialis retailer untuk Alat TEST AIR, TEST UDARA, TEST TANAH, MAKANAN, LABORATORIUM TEMPERATURE , ALAT Pemadam API/ APAR ( Fire Extinguisher) dengan merek APPRON, PATRON, YAMATO, DOCTOR FIRE, ALTEX, VIKING & PROTEC dll. Dengan Produk- produk yang kami tawarkan tsb tentunya berkualitas bagus. Karena Komitmen Perusahaan kami disini akan selalu memberikan pelayanan yang terbaik untuk para Mitra Kerja kami, Terima Kasih.

Tampilkan Lebih Banyak
EXCLUSIVE 5 Tahun
 
Jalan Hayam Wuruk No.127 Gedung Lindeteves Trade Centre (LTC) Lt.1 Blok C-32 No.8 , GLODOK (11180 ) Jakarta - INDONESIA
DKI Jakarta - Jakarta Barat
Login Terakhir 30-09-2024
081362449440
081362449440
6281362449440

Produk Lainnya


CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan