Spesifikasi Hioki 3198 Power Quality Analyzer

Hioki 3198 Power Quality Analyzer

         Verify power problems in accordance with the IEC61000-4-30 Class A standard

         Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz

         Optional GPS BOX for synchronizing multiple devices

 

Product Details

HIOKI 3198 Power Quality Analyzer IEC61000-4-30 Class A Standard – PW 3198 PQA The New World Standard for Power Quality Analysis, with recording & analyzing according to Class A requirements for PQAs

Verify power problems in accordance with the IEC61000-4-30 Class A standard. High Accuracy and continuous gapless recording (V:±0.1% of nominal voltage, A and W:±0.2% rdg. ±0.1% f.s.). CAT IV 600V - safe enough for incoming power lines. Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz. Wide dynamic range from low voltages up to 1300V (3P4W line-to-line voltage). Maximum 6000V transient overvoltage up to 700kHz. LAN, USB and SD card interfaces. Optional GPS BOX for synchronizing multiple devices.

Voltage can be measured with the main unit alone. An optional current sensor is necessary to measure current or power parameters. Use Model 9624-50 PQA-HiVIEW PRO (version 2.00 or later) with a PC to analyze the data collected to the SD card.

Measurement line type : Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel (must be synchronized to reference channel during AC/DC measurement)

 

Voltage ranges : Voltage measurement: 600.00 V rms

Transient measurement : 6.0000 kV peak

Current ranges : 500.00 mA to 5.0000 kA AC (depends on current sensor in use)

Basic accuracy : Voltage: ±0.1% of nominal voltage

Current : ±0.2% rdg. ±0.1% f.s. + current sensor accuracy

Active power : ±0.2% rdg. ±0.1% f.s. + current sensor accuracy

 

Measurement items :

1. Transient over voltage : 2MHz sampling.

2. Frequency cycle : Calculated as one cycle, 40 to 70Hz

3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle.

Current (1/2) RMS: half-cycle calculation.
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15

8. Frequency: Calculated as 10 or 12 cycles, 40 to 70Hz

9. 10-sec frequency: Calculated as the whole-cycle time during the specified 10s period, 40 to 70Hz

10. Voltage waveform peak, Current waveform peak

11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor (negative-phase, zero-phase)

12. High-order harmonic component (voltage/ current): 2kHz to 80kHz

13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50th orders

14. Harmonic voltage-current phase angle: 1th to 50th orders

15. Total harmonic distortion factor (voltage/ current)

16. Inter harmonic (voltage/ current): 0.5Hz to 49.5Hz

17. K Factor (multiplication factor)
18. IEC Flicker, ? V10 Flicker
 

Record : 55 weeks (with repeated recording set to [1 Week], 55 iterations) 35 days (with repeated recording set to [OFF])

Interface : SD/SDHC card, RS-232C, LAN (HTTP server funtion), USB2.0

Display : 6.5-inch TFT color LCD (640×480 dots)

Power supply : AC ADAPTER Z1002 (12V DC, Rated power supply 100V AC to 24 V AC, 50/60Hz)

BATTERY PACK Z1003 (Ni-MH 7.2V DC 4500mAh)

Dimensions, mass 300mm(11.81in)W × 211mm(8.31in)H × 68mm(2.68in)D (excluding protrusions), 2.6kg(91.7oz) (including battery pack)

Supplied accessories : Instruction manual×1, Measurement guide×1, VOLTAGE CORD L1000×1 set, Spiral Tube×1, Input Cable Labels×1, AC ADAPTER Z1002×1, Strap×1, USB cable (1m 3.28ft length)×1, BATTERY PACK Z1003×1, SD MEMORY CARD 2GB Z4001×1

Tampilkan Lebih Banyak

Digital Instrument

Selamat Datang Di

Digital Instrument - Industrial Equipment Online Store

 

Industrial Equipment - Menjual Berbagai Macam Peralatan Kebutuhan Industri Seperti :

Surveying : Total Station, Digital Theodolite, Automatic Level / Waterpass, Hand Level, Measuring Tape, Measuing Wheel, Laser Distance Meter, Range Finder.

Geology Tools : Compass, Clinometer, Rain Gauge, Altimeter, Palu, Current Meter.

Global Positioning System ( GPS) : Navigation, Aviation, Marine, Sport, Handheld, Geodetic dan Mapping.

Electrical Test Tool : Clamp Meter, Multimeter, pH Meter, Vibration Meter, Sound Level Meter, Light Meter, Thermometer, Anemometer, Tachometer, Oscilloscope, Spectrum Analyzer, Power Supply, Frequency Counter, Function Generator, Audio Generator, Signal Generator.

Communication : Handy-Talkie, Repeater, Satelite Phone.

Teropong : Binocular, Monocular, Telescope, Microscope.

Tampilkan Lebih Banyak

Digital Instrument

Free Member
 
Jl. Pesantren No.64
DKI Jakarta - Jakarta Pusat
Login Terakhir 12-06-2014
02136495554
081331170440

Produk Lainnya


Rp. 10 / pcs
PT.GLOBAL PRIMA PERKASA
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
Rp. 64.800.000 / unit
Mitra Laser
CALL
Alat Uji Lingkungan