Hanna HI-96101 Bromine, Chlorine, Cyanuric Acid, Iron Iodine and pH Portable Photometer
Perhatian!
Spesifikasi Hanna HI-96101 Bromine, Chlorine, Cyanuric Acid, Iron Iodine and pH Portable Photometer
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
The HI 96101 measures Bromine, Free and Total Chlorine, Cyanuric Acid, Iron, Iodine and pH content in water and wastewater samples. The reagents are in powder and liquid form depending on the parameter and they are supplied in dropper bottles and packets.
This multiparameter photometer can save time and money. If you need a simple, but professional meter measuring the most important constituents of water, especially in pools and spas, then HI 96101 has been designed for you.
The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both the measurement and calibration (zeroing) cuvettes are optically identical to provide the same measuring conditions.
Spesification :
Range | Bromine | 0.00 to 10.00 mg/L (ppm) |
Cl, Free | 0.00 to 5.00 mg/L (ppm) | |
Cl, Total | 0.00 to 5.00 mg/L (ppm) | |
CYA | 0 to 80 mg/L (ppm) | |
Iodine | 0.0 to 12.5 mg/L (ppm) | |
Iron LR | 0.00 to 1.60 mg/L | |
pH | 6.5 to 8.5 pH | |
Resolution | Bromine | 0.01 mg/L (ppm) |
Chlorine | 0.01 mg/L under 3.50 mg/L; 0.10 mg/L above 3.50 mg/L |
|
CYA | 1 mg/L (ppm) | |
Iron LR | 0.01 mg/L | |
pH | 0.1 pH | |
Accuracy @25°C | Bromine | ±0.08 mg/L ±3% of reading |
Chlorine | ±0.03 mg/L ±3% of reading | |
CYA | ±1 mg/L ±15% of reading | |
Iodine | ±0.1 mg/L ±5% of reading | |
Iron LR | ±0.01 mg/L ±8% of reading | |
pH | ±0.1 pH | |
Light Source | tungsten lamp | |
Light Detector | silicon photocell with narrow band interference filter @ 525 nm | |
Power Supply | 9V battery | |
Auto-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder | |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") | |
Weight | 360 g (12.7 oz.) | |
Method | Bromine | adaptation of the EPA, DPD method |
Chlorine | Adaptation of the USEPA method and Standard Method 4500-Cl G | |
CYA | adaptation of the turbidimetric method | |
Iodine | adaptation of the EPA, DPD method | |
Iron LR | adaptation of the TPTZ method | |
pH | Phenol Red method | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
DarmatekInstrument
DARMATEK berasal dari sebuah Toko yang berdiri sekitar tahun 2010 yang bergerak di bidang alat-alat safety, teknik dan elektronik.
Karena seiring dengan waktu dan perkembangan yang begitu pesat maka kami mencoba untuk memasarkan secara online berbagai Produk dan Merk di bidang Safety, Teknik, Electronic, Survey, Sirene, Laboratory, dLL. Tujuannya agar market kami dapat menjangkau seluruh wilayah Indonesia.
Toko online kami berkomitmen mengedepankan Pelayanan yang maksimal dengan melakukan efisiensi waktu, dan biaya, sehingga para konsumen tidak perlu lagi " memusingkan diri " dalam pemesanan barang. Anda pesan, harga deal, kami antar barang anda.
Kami juga menyediakan alat alat untuk keperluan Survey dan Laboratorium seperti: Total Station, Auto Level, Theodolite, Lasermeter pengukur Jarak, Teropong/ Binocullar, Nightvision, Kompas, Altimeter, Anemometer, Weather Station, Lux Meter, Thermometer Hygrometer dst dengan ditunjang merek-merek yang sudah terkenal di dunia survey seperti : TOPCON, SOKKIA, NIKON, SOUTH, HORIZON, LEICA, GARMIN, SUUNTO, BRUNTON, LUTRON, SMART SENSOR, DAVIS, LUTRON, SANFIX, PCE, SANWA, TENMARS, PCE, SEW, PROTEK, AZ INSTRUMENT, SIRINE, ATTEN, OWON, DEKKO, AMPROBE, ATAGO dan lain-lain.
Darmatek terus berupaya melakukan perbaikan dan penyempurnaan diri sebagai Wujud Partisipasi aktif untuk memajukan Industri di berbagai bidang di Indonesia dengan “ Kwalitas dan Harga terbaik”