HANDHELD FLUE GAS ANALYZER A550
Update Terakhir
20-06-2015
Minimum Pembelian
1 Set
Dilihat Sebanyak
171 kali
Lokasi
Banten - Tangerang Selatan
Harga
Kontak Kami
Bagikan
+ Penawaran
Perhatian!
Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi lebih aman.
Spesifikasi HANDHELD FLUE GAS ANALYZER A550
Type : A550
Produk : Wohler - Jerman
Fungsi : Untuk mengukur Gas O2, CO, NO/ NOx. SO2, NO2
Technical data
A. Oxygen concentration ( O2) in flue gas
• Range : 0.0 – 21.0 vol. %
• Accuracy : ± 0.3 Vol. %
B. Carbon monoxide ( CO 4, 000 ppm) in flue gas ( Wohler A 550)
• Range : 0 – 4, 000 vol. ppm; resolution 1 vol. ppm
• Accuracy : 20 ppm ( < 400 ppm) , otherwise 5 % of reading
C. Carbon monoxide ( CO) in flue gas ( Wohler A 550 L)
• Range : 0 – 35, 000 vol. ppm; resolution 1 vol. ppm
• Accuracy : ± 100 ppm ( < 1, 000 ppm) , otherwise 10 % of reading ( with H2 < 5% of reading)
D. Carbon monoxide ( COhigh) in flue gas ( optional)
• Range : 0 – 100, 000 vol. ppm; resolution 1 vol. ppm
• Accuracy : ± 100 ppm ( < 1, 000 ppm) , otherwise 10 % of reading ( with H2 < 5 % of reading)
E. Nitric oxide concentration ( NO) in flue gas ( optional)
• Range : 0 – 3, 000 vol. ppm ( continuously up to 1, 000) ;
• Resolution : 1 vol. ppm
• Accuracy : ± 5 Vol.-ppm ( < 100 ppm) , otherwise 5 % of reading
F. Nitrogen dioxide concentration ( NO2) in flue gas ( optional)
• Range : 0 – 1000 vol. ppm ( continuously up to 200) ; resolution 1 vol. ppm
• Accuracy : ± 5 vol. ppm ( < 100 ppm) , otherwise 5 % of reading
G. Sulfur dioxide ( SO2) in flue gas ( optional)
• Range : 0 – 5, 000 vol. ppm; resolution 1 vol. ppm
• Accuracy : ± 10 vol. ppm ( 0...200 ppm) , otherwise 5 % of reading
H. Chimney draft / differential pressure ( PD) with 4 Pa test ( Wohler A 550)
• Range : 0.00 to ± 44.16 inWC; resolution 0.004 inWC ( < 4.01 inWC) , otherwise 0.004 inWC, with ventilation loss measurement 0.004 inWC
Accuracy : 0.0012 inWC ( < 0.04 inWC) , otherwise 3 % of reading
Drift < 0.00081 inWC in 5 minutes
Chimney draft / differential pressure ( PD) ( Wohler A 550 L)
Display : inWC
I. Measurement principle : Semi-conductor diaphragm
• Range : 0.00 to ± 44.16 inWC; resolution 0.004 inWC
• Accuracy : 0.008 inWC ( < 0.16 inWC) , otherwise 5 % of reading
Flue gas temperature ( TS)
• Display : ° F
J. Measurement principle : Thermocouple ( NiCr-Ni) ( NiCr-Ni)
• Range : -4 ° F to 1, 472 ° F; resolution 32.18 ° F
• Accuracy : 32 – 271.4 ° F: ± 35.6 ° F , 271.4 – 1, 472 ° F: ± 1.5 % of reading Combustion air temperature ( TA)
• Display : ° F
K. Measurement principle : Thermocouple ( NiCr-Ni)
• Range : -4 ° F to 212 ° F; resolution 32.2 ° F
• Accuracy : ± 33.8 ° F
L. Wood moisture
• Range : 10.0 – 40.0 % ; resolution 0.1 %
• Accuracy : ± 40 % of reading tested to VDI 4206 Part 4
• Power supply : Lithium-Ion, rechargeable battery 3.7 V, 5800 mAh, charges via USB
• Battery operating time : Approx. 12 h ( depends on operating status and display illumination)
• Storage temperature : -4 ° F to + 122 ° F
• Operating temperature : + 41 – 104 ° F to maintain stated accuracy
• Weight : 2.75 lbs
• Dimensions : 8.7 " x 6.3 " x 2.2 " ( without probe)
• Length of cable-hose : 67 "
Produk : Wohler - Jerman
Fungsi : Untuk mengukur Gas O2, CO, NO/ NOx. SO2, NO2
Technical data
A. Oxygen concentration ( O2) in flue gas
• Range : 0.0 – 21.0 vol. %
• Accuracy : ± 0.3 Vol. %
B. Carbon monoxide ( CO 4, 000 ppm) in flue gas ( Wohler A 550)
• Range : 0 – 4, 000 vol. ppm; resolution 1 vol. ppm
• Accuracy : 20 ppm ( < 400 ppm) , otherwise 5 % of reading
C. Carbon monoxide ( CO) in flue gas ( Wohler A 550 L)
• Range : 0 – 35, 000 vol. ppm; resolution 1 vol. ppm
• Accuracy : ± 100 ppm ( < 1, 000 ppm) , otherwise 10 % of reading ( with H2 < 5% of reading)
D. Carbon monoxide ( COhigh) in flue gas ( optional)
• Range : 0 – 100, 000 vol. ppm; resolution 1 vol. ppm
• Accuracy : ± 100 ppm ( < 1, 000 ppm) , otherwise 10 % of reading ( with H2 < 5 % of reading)
E. Nitric oxide concentration ( NO) in flue gas ( optional)
• Range : 0 – 3, 000 vol. ppm ( continuously up to 1, 000) ;
• Resolution : 1 vol. ppm
• Accuracy : ± 5 Vol.-ppm ( < 100 ppm) , otherwise 5 % of reading
F. Nitrogen dioxide concentration ( NO2) in flue gas ( optional)
• Range : 0 – 1000 vol. ppm ( continuously up to 200) ; resolution 1 vol. ppm
• Accuracy : ± 5 vol. ppm ( < 100 ppm) , otherwise 5 % of reading
G. Sulfur dioxide ( SO2) in flue gas ( optional)
• Range : 0 – 5, 000 vol. ppm; resolution 1 vol. ppm
• Accuracy : ± 10 vol. ppm ( 0...200 ppm) , otherwise 5 % of reading
H. Chimney draft / differential pressure ( PD) with 4 Pa test ( Wohler A 550)
• Range : 0.00 to ± 44.16 inWC; resolution 0.004 inWC ( < 4.01 inWC) , otherwise 0.004 inWC, with ventilation loss measurement 0.004 inWC
Accuracy : 0.0012 inWC ( < 0.04 inWC) , otherwise 3 % of reading
Drift < 0.00081 inWC in 5 minutes
Chimney draft / differential pressure ( PD) ( Wohler A 550 L)
Display : inWC
I. Measurement principle : Semi-conductor diaphragm
• Range : 0.00 to ± 44.16 inWC; resolution 0.004 inWC
• Accuracy : 0.008 inWC ( < 0.16 inWC) , otherwise 5 % of reading
Flue gas temperature ( TS)
• Display : ° F
J. Measurement principle : Thermocouple ( NiCr-Ni) ( NiCr-Ni)
• Range : -4 ° F to 1, 472 ° F; resolution 32.18 ° F
• Accuracy : 32 – 271.4 ° F: ± 35.6 ° F , 271.4 – 1, 472 ° F: ± 1.5 % of reading Combustion air temperature ( TA)
• Display : ° F
K. Measurement principle : Thermocouple ( NiCr-Ni)
• Range : -4 ° F to 212 ° F; resolution 32.2 ° F
• Accuracy : ± 33.8 ° F
L. Wood moisture
• Range : 10.0 – 40.0 % ; resolution 0.1 %
• Accuracy : ± 40 % of reading tested to VDI 4206 Part 4
• Power supply : Lithium-Ion, rechargeable battery 3.7 V, 5800 mAh, charges via USB
• Battery operating time : Approx. 12 h ( depends on operating status and display illumination)
• Storage temperature : -4 ° F to + 122 ° F
• Operating temperature : + 41 – 104 ° F to maintain stated accuracy
• Weight : 2.75 lbs
• Dimensions : 8.7 " x 6.3 " x 2.2 " ( without probe)
• Length of cable-hose : 67 "
SEGITIGA MAS
Environment, healthy lab equipment supplier and contractor
SEGITIGA MAS
Free Member
Graha Raya, Cluster Gardenia Loka F7 15 Serpong, Tangerang Selatan - BANTEN
Banten - Tangerang Selatan
Login Terakhir 24-10-2015
+6221 2944 5820
085206001539
Produk Lainnya