Spesifikasi JENCO 6309POT pH, ORP, Temperature In-line Analyzer

 
 
6309POT

6309POT

Description

pH & ORP analyzer,1/4 DIN panel mount IP-65 case. Features 2 pH and 2 ORP fully programmable relays and one for temperature. RS-485 interface, password protected with individual ID's. 4-20 mA analog output is fully programmable, assignable & reversible. Graphical display. Tinned lead connectors. CE Approved.
  • Ph/ORP/temp. measurement & control
  • Display pH electrode efficiency
  • Reversible & isolated 4~20ma output
  • RS-485 output
  • Bumpless calibration
  • Graphic LCD dispaly,128 x 64with backlight
  • Membrane switch with audio feedback
  • Auto temp. compensation
  • High 50/60 hz noise rejection
  • Pipe/wall/panel mounting
  • 1/4 DIN watertight enclosure
  • One programmable relay for temp.
  • CE approved
  • Programmable linear/ ORP current output or programmable linear/ anti-logarithmic current output

Specifications

  •   RANGE RESOLUTION ACCURACY
    pH -2.00 to 16.00 0.01pH 0.1% ± 1 LSD
    ORP(Absolute) -2500 to 2500mV 1mV ±0.1% rdg ± 1mV
    ORP(Relative) -6499 to 6499mV 1mV ±0.1% rdg ± 1mV
    Temp. -10.0 to 120 °C 0.1°C ± 0.3°C
  • pH

    • Temperature compensation range: -10.0 to 120.0 °C
    • Buffer recognition: 4.01,7, 10.01 / 4.00,6.86, 9.18
    • Buffer temperature range: 0 to 60.0 °C
    • Electrode slope compensation: ±30% of ideal slope
    • Electrode offset compensation: ±100 mV
    • Input impedance: Greater than 10 exp(13) ohms
    • Calibration auto end point sensing: Yes

    Output Relays

    • pH: 2programmable high or 2 low
    • ORP: 2programmable high or 2 low
    • Temperature: 1programmable high or 1 low
    • Control type: On/off
    • Relay output (resistive load only): 5amps at 115 VAC 2.5 amps at 230 VAC
    • Relay set point hysteresis: User programmable

    Current Output

    • Type: Isolated 4 to 20 mA
    • Range: Selectable zero, & span
    • Accuracy: ±0.02mA
    • Isolated voltage: 500 VDC
    • Maximum load: 500 w

    General

    • ATC sensor: Thermistor 10kiloohms at 25 c
    • Security protection: 4digit password
    • Keypad: Audio feedbackup
    • Communication: RS-485
    • Pre-amplifier voltage: ±5 VDC,20mA max output
    • Power source: 115/230 VAC, 50/60hz
    • Dimensions: 1/4 DIN, depth 148mm
    • Weight: 950 gm
Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Free Member
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


Rp. 10 / pcs
PT.GLOBAL PRIMA PERKASA
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
Rp. 64.800.000 / unit
Mitra Laser
CALL
Alat Uji Lingkungan