KOEHLER K71000 Automatic Pensky-Martens Closed Cup Flash Point Analyzer

Update Terakhir
10-02-2016
Dilihat Sebanyak
164 kali
Lokasi
Jawa Barat - Bekasi
Harga
Kontak Kami
Bagikan
+ Penawaran

Perhatian!

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi lebih aman.

Spesifikasi KOEHLER K71000 Automatic Pensky-Martens Closed Cup Flash Point Analyzer

 

Test Method 
For flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing. .

Automated Pensky-Martens Flash Point Analyzer
• Conforms to ASTM D93 and related specifications
• Flash Point Detection by Thermocouple and Ionization Ring 
• Electric or Gas ignition: Software selectable, User Friendly Manual Switching
• Flash Point operation range between Ambient and 405°C
• Integrated Dual Fan System directly cools test cup and surrounding environment
• 8.4” LCD Touch Screen Interface makes for easy viewing and navigation
• Automatic Barometric Pressure Correction
• Fire Suppression System floods instrument with inert gas in the event of a fire

The Automated Pensky-Martens Flash Point Analyzer represents a perfect union of next-generation technology with traditional robust quality. The system software runs on an integrated processor PC running the latest Windows operating system. The 8.4” touch screen interface fully displays all operator parameters and results on a single screen. A three (3) position mechanical lift system for the cover and motor assembly is fully automated and software selectable: Open – Clean – Test for one touch positioning of the test cup. Comes standard with two flash detector systems including a thermocouple and ionization ring detection. Over 65,000 results of data can be stored on the local hard drive. Integrated Dual Fan System directly cools the test cup and the environment around test cup. Unlimited number of user programs including a quick test that safely tests from ambient, puts the flash point result into the EFP of the official run, and prompts user to refresh the sample, virtually assuring no fires ever occur. In addition, the instrument comes standard with an inert gas fire suppression system.





Click on the image to view a larger photo of the instrument.

 

Specifications 
Conforms to the specifications of:
ASTM D93 Procedure A, B and C; IP 34; ISO 2719; DIN EN 22719; 
JIS K2265; NF M 07-019
Detection System: Thermocouple and Ionization Ring
Temperature Range: Ambient - 405°C 
Heating Rate: In accordance to ASTM D93 procedure A, B and C
Stirring Rate: 0 to 300 ± 5 RPM, 
Cycle Time:5 minutes as per rapid fan cooling system
Ignition Test Frequency: User selectable on per method basis
Cooling: Integrated Dual Fan System: First (1) directly to cup, Second
(2) to cool environment around test cup
Barometric Pressure: Automatic Barometric Pressure Correction
Methods & Data Storage: Limited only by PC hard disk drive space
Temperature Calibration: Three Types come standard:
- 2 Point Sample Temperature
- Multipoint (>2) Temperature Calibration
- CRM Calibration – Built-In Software function to automatically correct
as per CRM tested
Communication: - LIMS Connectivity via Ethernet and RS 232 ports
- Two (2) USB ports (1 – Frontm 2 – Back)
Security: Three (3) level password protection
Safety: Fire prevention, detection, and suppression systems standard
Electrical Requirements:
110-240V 50/60Hz

Dimensions wxdxh,in.(cm)
10.875 x 17.5 x 26 (27.63x44.45x66.04)
Net Weight: 60 lbs (27.22kg)

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Free Member
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


Rp. 10 / pcs
PT.GLOBAL PRIMA PERKASA
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
Rp. 64.800.000 / unit
Mitra Laser
CALL
Alat Uji Lingkungan