KOEHLER K87700/K87790 Automatic Tag Closed Cup Flash Point Tester

Update Terakhir
10-02-2016
Dilihat Sebanyak
153 kali
Lokasi
Jawa Barat - Bekasi
Harga
Kontak Kami
Bagikan
+ Penawaran

Perhatian!

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi lebih aman.

Spesifikasi KOEHLER K87700/K87790 Automatic Tag Closed Cup Flash Point Tester

 
Test Method
For flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash point below 200°F (93°C) except cut-back asphalts, those liquids which tend to form a surface film under test conditions and materials which contain suspended solids.

Features and Benefits

• Conforms to ASTM D56 and related specifications

• Simple automation routine for easy operation




Click on the image to view a larger photo of the instrument.

  Automatic Tag Closed Cup Flash Point Tester
The automated Tag Closed Cup flash point tester ensures the accuracy and precision required according to the ASTM D56 and related test methods. The test sample is heated at a prescribed rate of temperature increase throughout the standard temperature test range to 100°C. The flash point tests are simply conducted by mounting the flash cup filled with sample into the test position and selecting a pre-programmed test method or the search mode to determine an approximate flash point. The automation routines provide accurate test results. Ignition by gas flame or electrical ignitor is included, along with safety cut-off devices. The measurement range can be extended to –-30°C by any appropriate external chiller. Supervision software is included.

Specifications
Conforms to the specifications of:
ASTM D56; IP 304

Electrical Requirements

115/230V 60/50Hz, Single Phase

Dimensions lxwxh,in.(cm)
21 x10.5x19.75 (53.5x26x50) 
Net Weight: 
44 lbs (20kg)
Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Free Member
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
Rp. 123 / Unit
ALAT KESLING INDONESIA
Rp. 123 / Unit
ALAT KESLING INDONESIA