KOEHLER K14600 Tag Closed Cup Flash Tester

Update Terakhir
10-02-2016
Dilihat Sebanyak
75 kali
Lokasi
Jawa Barat - Bekasi
Harga
Kontak Kami
Bagikan
+ Penawaran

Perhatian!

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi lebih aman.

Spesifikasi KOEHLER K14600 Tag Closed Cup Flash Tester

 
Test Method
For flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash point below 200°F (93°C) except cut-back asphalts, those liquids which tend to form a surface film under test conditions and materials which contain suspended solids.

Features and Benefits
• Conforms to ASTM D56 and related specifications

• Gas or electrical heating


Click on the image to view a larger photo of the instrument.

  K14600 Tag Closed Cup Flash Tester
Determines flash points of liquid products by the Tag Closed Cup method. Features stepless variable heat control with reference dial for accurate repeat setting of temperature rate of rise per specifications. Also available with gas burner instead of electric heater. Precision machined cover mechanism simultaneously opens slide shutter and applies test flame to sample at the turn of a knob. Includes liquid bath with constant level overflow, brass test cup, plated brass thermometer ferrules and test flame reference bead. Bath and cover mechanism are constructed of plated brass. Heater is enclosed in a cast aluminum base assembly.

Specifications
Conforms to: ASTM D56; IP 304; FTM 791-1101

Electrical Requirements
115V 50/60Hz, Single Phase, 1.3A
220-240V 50/60Hz, Single Phase, 0.6A

Included Accessories
Brass Test Cup
Cover Assembly (includes Slide Shutter, Burner and Thermometer Ferrules)

Dimensions lxwxh,*in.(cm)
5x5x16 (13x13x41)
*with thermometers inserted
Net Weight: 7 lbs (3.2kg)

Shipping Information
Shipping Weight: 8 lbs (3.6kg)
Dimensions: 0.76 Cu. ft.

Ordering Information
 
Catalog
Number
Product Description
Electrical Requirements
K14600
Electrically Heated Model
115V 50/60Hz
K14670 Electrically Heated Model
220-240V 50/60Hz
K14690
Gas Heated Model  

Accessories
 
Catalog
Number
Product Description
Temperature Range
250-000-09F
ASTM 9F Thermometer
20 to 230°F
250-000-09C
ASTM 9C Thermometer
-5 to +110°C
250-000-57F
ASTM 57F Thermometer
-4 to +122°F
250-000-57C ASTM 57C Thermometer
-20 to +50°C
K14510 Cover Assembly
Includes slide shutter burner and thermometer ferrules
 
K14520
Brass Test Cup
Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Free Member
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
Rp. 123 / Unit
ALAT KESLING INDONESIA
Rp. 123 / Unit
ALAT KESLING INDONESIA