KOEHLER K95500 Digital Penetrometer & Data Acquisition Software

Update Terakhir
10-02-2016
Dilihat Sebanyak
65 kali
Lokasi
Jawa Barat - Bekasi
Harga
Kontak Kami
Bagikan
+ Penawaran

Perhatian!

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi lebih aman.

Spesifikasi KOEHLER K95500 Digital Penetrometer & Data Acquisition Software

 
Test Method
Penetration tests are performed on petroleum products to determine consistency and shear stability (lubricating greases) for design, quality control and identification purposes. A standard cone or needle is released from a penetrometer and allowed to drop freely into the sample for 5 seconds (or a different specified interval) at constant temperature. The depth of penetration of the cone or needle into the sample is measured in tenths of a millimeter by the penetrometer.

Features and Benefits
• Tests the consistency of lubricating greases, petroleum waxes, bitumens, pastes, creams and other solid to semi-solid products

• Automatically timed operator programmable penetration measurements

• Motorized placement of penetrator on sample surface

• Large LCD to display all functions

• RS232 port for data transfer

• Full measurement range of 0-620 in 1/10mm scale or 1/100mm scale

• Rechargeable battery or AC operation

• Large, removable base accommodates grease worker cups and other ASTM and non-standard sample containers

• Complete selection of penetrometer cones, needles and accessories for petroleum products testing and for a wide range of other applications

• Conforms to all ASTM, IP, ISO 9001 and related specifications for penetrometers




Click on the image to view a larger photo of the instrument.

K95500 Microprocessor-Based Digital Penetrometer
  A new microprocessor based penetrometer loaded with advanced features to provide ease of operation and highly reproducible consistency measurements of petroleum products. Microprocessor control provides a full range of measurement and reporting options, and operation is simplified by four user programmable presets that facilitate lowering the penetrator tip to the sample surface.

Automatically timed penetrations—The penetrometer defaults to the standard ASTM interval of 5.0 seconds, or the operator may conveniently program a different interval in the range between 0.1 and 9999.9 seconds (in 0.1 second increments). A curing or temperature stabilization period may also be programmed by the operator (to delay the release of the penetrator into the sample) and for added convenience all selected parameters are retained in memory and automatically repeated in subsequent tests until changed by the operator. Separate keypad controls for each parameter simplify operation. Penetration and delay intervals count down on a large, easy to read LCD on the head of the unit.

Convenient measurement and reporting options—Penetration measure-ments in the full range of 0 - 620 in 1/10mm scale are reported in either 1/10mm or 1/100mm increments at the operator’s option. For quality control testing, a penetration range can be entered into memory prior to testing. If a test result falls outside of the programmed range, an audible signal and visual error message alert the operator of a failed sample. Test results are displayed in digital format on a large LCD readout on the head of the penetrometer and can be communicated to a printer or computer via a built-in RS232 interface.

Simplified penetrator tip placement—Correct placement of the penetrator tip on the sample surface is essential for accurate penetration test results. The Koehler Digital Penetrometer has four operator programmable presets that lower the penetrator to the sample surface height at the touch of a button, greatly simplifying the process to ensure reproducibility. A fine adjustment button permits slight adjustments as needed. Full manual operation is also available with the use of coarse and fine push button controls and built-in magnifier and illuminator arms. When testing electrically conductive samples, a built-in circuit senses the sample surface for automatic placement. After testing, the penetrometer head returns to a raised position at the touch of a button to facilitate cleaning of the penetrator and changing of the sample.

More convenience features—The detachable machined base provides a large platform to accommodate a wide range of sample containers and constant temperature cylinders. It removes easily to permit the head assembly to be reversed (for use with a constant temperature bath) or mounted directly to a bath housing or other location. A built-in rechargeable battery pack permits field operation and provides back-up in the event of power interruption. Battery recharges automatically during operation of the penetrometer on standard AC electrical service.

Specifications
Conforms to the specifications of: ASTM D5, D217, D937, D1321, D1403, D2884, D4950; IP 49, 50, 179, 310; ISO 2137; DIN 51804, 51580, 51579; FTM 791-311, 791-312, 791-313; AOCS Cc 16-60; AACC 58-14; NF T 60-119; 60-123; 60-132; 66-004

Penetration Range: 0-62.0mm (0-620 penetration scale) in 1/10mm or 1/100mm

Penetration Interval: Operator variable from 0.1 to 9999.9 seconds with automatic repeat function and 5.0 second default

Included Accessories
Standard Plunger, 47.5g
Weights, 50 and 100g

Dimensions lxwxh,in.(cm)
Base: 12.5x14 (31.7x35.6)
Overall: 12.5x14x18 (31.7x35.6x45.7)
Net Weight: 35 lbs (15.9kg)

Shipping Information
Shipping Weight: 27 lbs (12.3kg)
Dimensions: 2 Cu. ft.

K95500-SFW Penetrometer Software
  Penetrometer Software automatically retrieves complete test parameters and final results on each penetration test for hands-free data acquisition. In addition, the software will determine test averages, standard deviations, and ASTM test repeatability as well as maintain instrument and accessory calibration information. Yield stress values are calculated as per ASTM D2884, and full penetration values (ASTM D217) are automatically determined from the 1/4 and 1/2 scale ASTM D1403 tests. The sophisticated Windows®-based software package features an easy-to-navigate operation, a straightforward user interface, minimal draw on Windows® memory resources, an automatic real-time data acquisition via RS232 connection, and a timer / stopwatch feature for general laboratory use. The "test intelligent" software simplifies the process by automatically choosing the standard test parameters when selecting a specific penetration ASTM method. These default values are easily changed by the user. The test results are easily printed in accordance with ISO guidelines. The software package requires no PC hardware installation and includes the software installation CD and computer connection cable.

Computer Requirements
PC Processor: Intel® Pentium II or similar (minimum)
Processor Speed: 500 MHz or higher
Operating System: Windows ® 98 SE, 2000, NT, ME, XP
Memory (RAM): 64 Mb RAM (128 Mb RAM recommended)
Hard Disk Space: 15 Mb free space (minimum)
Communication Port: one RS232 port
Other Software: Microsoft ® Excel (97 or above)

For a complete demonstration of the Penetrometer Software Package and its capabilities, please download a copy of the demo version (6.6MB file). After installing the demo software, you will be prompted to quickly register the demo with Koehler via email.

Click here to download the software demo.

Ordering Information
 
Catalog
Number
Product Description
Electrical Requirements
K95500 Digital Penetrometer 115V, 50/60Hz
K95590 Digital Penetrometer 220-240V, 50/60Hz
K95500-SFW Penetrometer Software  

Accessories
 
Catalog
Number
Product Description
K19552
Calibration Kit
Consists of 0.500, 1.000, and 2.000" gauge blocks with calibration certificate traceable to NIST
K95573
Plunger, 15g
For use with K20200, K19800, and K20300 Cones
K95519
Plunger, 6.9g
For use with K20900 Cone
K95577 Standard Plunger, 47.5g
K19587 Loading Weight, 50g
K19588
Loading Weight, 100g

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Free Member
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


Rp. 10 / pcs
PT.GLOBAL PRIMA PERKASA
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
CALL
Alat Uji Lingkungan
Rp. 64.800.000 / unit
Mitra Laser
CALL
Alat Uji Lingkungan