KOEHLER K41100 Determination of Carbon Residue (Micro Conradson Method)

Update Terakhir
10-02-2016
Dilihat Sebanyak
82 kali
Lokasi
Jawa Barat - Bekasi
Harga
Kontak Kami
Bagikan
+ Penawaran

Perhatian!

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi lebih aman.

Spesifikasi KOEHLER K41100 Determination of Carbon Residue (Micro Conradson Method)

 

K41100 Determination of Carbon Residue (Micro Conradson Method)
• Maximum Test Temperature: 550°C
• Temperature measurement Resolution: 1°C
• Furnace Cooling: by compressed air injection
• Automatically controlled atmosphere
• Maximum load of samples: 
12 small vials / 6 large vials




Click on the image to view a larger photo of the instrument.

 

Test Method
Determines the amount of carbon residue formed after evaporation and pyrolysis of petroleum materials under certain conditions and is intended to provide some indication of the relative coke forming tendency of such materials.

Specifications 
Conforms to the specifications of:
ASTM D4530; ISO 10370; IP 398; DIN 51551
Electrical Requirements:
230V 50/60Hz, 1500W

Shipping Information
Shipping Weight: 38 lbs (17.3kg)
Dimensions: lxwxh,in.(cm)
16x16x31 (40.6x40.6x78.8)

Dimensions lxwxh,in.(cm)
9.8x11.8x23.6 (25x30x60)
Net Weight: 33 lbs (15kg)

Included Accessories
Small Vial Holder
2 mL Borosilicate Vial (12)
Cleaning Cable
Basket Handle


Ordering Information
 
Catalog
Number
Product Description
K41100

Micro Carbon Residue Tester, 230V 50/60Hz

Accessories
 
Catalog
Number
Product Description
K41100-6
Holder for 2 ml vial (12 places)
K41100-7
Solenoid valve for nitrogen
K41100-8
Solenoid valve for air
K41100-9
Regulation thermocouple
K41100-10

Spare Static Relay

K41100-11

Condensate Trap - made of Glass

K41100-12

Condensate Trap - made of Brass

Consumables
 
Catalog
Number
Product Description
K41100-1
Holder for 16 ml vial (6 places)
K41100-2
Holder for both 16 mL and 2 mL vials (7 places)
K41000-2
2 ml Brosilicate glass sample vial, single use (MRC test)
K41000-3
16ml Borosilicate glass sample vial, single use (MRC test)
K41000-4

2 ml Quartz sample vial, re-usable (Ash Content test)

K41000-5

16 ml Quartz sample vial, re-usable (Ash Content test)

K41100-3

16 mL vials (pack of 144) for single use

K41100-4

2 mL vials (pack of 144) for single use

K41000-8

4 mL Borosilicate glass sample tube (ISO 10370 and IP 398)
Outside dia.: 12 mm / Height: 72 mm

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Kami CV ANDALAN PRIMA SEJAHTERA.

Alamat

Jl. Muchtar Tabrani, Bintang Metropol Blok A-7 No. 16 , Bekasi Utara

Phone    : 021 - 29253187, 29253184,  Fax : 021-29253186

Email     : support@andalanprimasejahtera.com / maria@andalanprimasejahtera.com

Website : www.andalanprimasejahtera.com

 

Yang berdiri sejak tahun 2005 adalah  distributor laboratory equipment, reagent, measuring  and test instrument

 

Perusahaan kami mengageni beberapa produk yaitu, peralatan untuk oil dan gas, lingkungan , Electrical, Kimia dan air

 

Perlu kami sampaikan pula bahwa kami mempunyai tenaga yang profesional dalam menangani pemasangan dan perbaikan alat/barang untuk keperluan laboratorium dan menjamin After Sales Service bagi barang atau peralatan yang kami supplay.

Tampilkan Lebih Banyak

ANDALAN PRIMA SEJAHTERA

Free Member
 
Jl. Muchtar Tabrani Perum. Bintang Metropol Blok A7 no 16
Jawa Barat - Bekasi
Login Terakhir 12-02-2019
02129253184
081290773137

Produk Lainnya


CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
CALL
ALAT KESLING INDONESIA
Rp. 123 / Unit
ALAT KESLING INDONESIA
Rp. 123 / Unit
ALAT KESLING INDONESIA